CLA-VAL 36 Series Installation, Operation & Maintenance Manual Download Page 1

Combination Air Valves

(Single Body Type)

Detail No.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

29

30

34

Part Name 

Body 

Cover 

Baffle

Seat

Float

Gasket

Cover Bolt

Retaining Screw

Guide Bushing

Float Arm

Orifice Button

Pivot Pin

Retaining Ring 

Pipe Plug

Cushion

Plug 

Float Retainer

Lock Nut 

Cushion Retainer

Washer (internal)

Washer (external)

INTRODUCTION

This  manual  will  provide  you  with  the  information  to  properly

install and maintain this valve to ensure a long service life.  The

valve has been designed with stainless steel trim to give years of

trouble-free  operation.    The  Combination  Air  Valve  is  typically

mounted at the high points in a piping system and performs the

functions of both an air release valve and air/vacuum valve. 

The Combination Air Valve automatically vents air which accu-

mulates at high points in a system during its operation.  The valve

will also exhaust and admit large quantities (volumes) of air dur-

ing filling or draining operations and after emergency conditions

such  as  a  power  failure.    Both  the  air  release  and  air/vacuum

functions are needed to maintain pipeline efficiency while provid-

ing protection from adverse pressure conditions.

The valve is a float-operated, resilient-seated valve designed to

handle fluids having minimal suspended solids.  The Maximum

Working Pressure and Model No. are stamped on the nameplate

for reference.

RECEIVING AND STORAGE

Inspect valves upon receipt for damage in shipment. Handle all

valves carefully without dropping.  Valves should remain boxed,

clean and dry until installed to prevent weather related damage.

For long term storage greater than six months, the valves must

remain in the box and stored indoors.  Do not expose valves to

sunlight or ozone for any extended periods.

DESCRIPTION OF OPERATION

The  Combination Air  Valve  is  fully  automatic  and  designed  to

continuously remove air accumulating at high points in a piping

system.  It also will exhaust and admit air during filing and drain-

ing of the pipeline or tank.  The valve, as shipped, is a normally

open valve and has three functions.

During  System  start-up,  the  open  valve  will  exhaust  large

quantities of air until fluid enters the valve.  The float will then

rise  and  press  the  orifice  button  located  in  the  float  arm,

against the plug stem and raise the plug.  Pressure within the

valve body will force the plug upward tightly against the seat.

When  system  is  drained  the  plug  will  open  allowing  air  to

reenter the system.

1.

Figure 1. Custom Combination Air Valve

Figure 2. 

Air Exhausted and Air

Intake During Pipeline

Fill and Drain.

As  air  accumulates  in  the  piping  system  and  enters  the

valve, the float drops and the orifice button breaks contact

with  the  plug  stem.   Accumulated  air  will  vent  through  the

plug stem.  As the air is vented, the float raises once again

and closes the plug stem orifice.  See Figure 2.

2.

INLET

Figure 3.

Accumulated Air

Continuously

Released

INLET

INSTALLATION / OPERATION / MAINTENANCE

Series

36

9

7

2

6

4

16

3

9

12

13

10

18

5

15

1

WORKING PRESSURE - 300 P.S.I.

TEST PRESSURE - 450 P.S.I.

14

8

11

17

29

30

34

18

14

FOR ILLUSTRATION ONLY
SPOKE SHOWN 90…
FROM ACTUAL ANGLE

34

Sizes 1” - 4” Threaded Inlet

Summary of Contents for 36 Series

Page 1: ...without dropping Valves should remain boxed clean and dry until installed to prevent weather related damage For long term storage greater than six months the valves must remain in the box and stored indoors Do not expose valves to sunlight or ozone for any extended periods DESCRIPTION OF OPERATION The Combination Air Valve is fully automatic and designed to continuously remove air accumulating at ...

Page 2: ...N PIPING With the inlet shut off valve open partially open the drain valve until flow can be heard If the air valve is working prop erly water should be exhausted from the drain valve If air is exhausted follow steps 2 6 1 Close the inlet shut off valve 2 Slowly open the drain valve to allow the fluid in the valve to drain If draining is difficult the valve may be clogged valve requires service 3 ...

Page 3: ...disassembled without removing it from the pipeline Or for convenience the valve can be removed from the line All work on the valve should be performed by a skilled mechanic with proper tools No special tools are required CAUTION The valve must be drained before removing the cover or pressure may be released causing injury Close inlet shut off valve Slowly open drain valve or remove drain plug Remo...

Page 4: ...ia Ave Costa Mesa CA 92627 Phone 949 722 4800 Fax 949 548 5441 E mail info cla val com www cla val com Copyright Cla Val 2018 Printed in USA Specifications subject to change without notice N 36 Series Single Body R 01 2018 ...

Reviews: