Page 1: ...UAL Read this Instruction Manual before using the product Read the safety notes carefully Keep this Instruction Manual in a safe and convenient place for future reference SM A14445 A 2 Electric Actuat...

Page 2: ...nge without notice The product is intended for users who have basic knowledge of materials wiring electricity and mechanisms CKD shall not be responsible for accidents caused by persons who selected o...

Page 3: ...ident To avoid this Thoroughly read and understand this Instruction Manual before using the product To explicitly indicate the severity and likelihood of a potential harm or damage precautions are cla...

Page 4: ...man life and body Mechanism and mechanical device for transferring and transporting people Critical parts for securing safety in a mechanical device WARNING Use the product within the specifications P...

Page 5: ...cifications 5 2 INSTALLATION 6 2 1 Environment 11 2 2 Unpacking 11 2 2 1 Parts of the product 11 2 3 Installing 12 2 3 1 Actuator 12 2 3 2 Objects transferred slide table upper surface 12 2 3 3 Object...

Page 6: ...r supply EA PWR KHNA480F 48 Surge protector AX NSF RAV 781BXZ 4 Noise filter AX NSF NF2015A OD Ferrite core 7 pieces EA NSF FC01 SET Provided for free Software for Windows S Tools PC setting software...

Page 7: ...ctric actuator ECR controller SM A10615 Electric actuator ECR controller IO Link specification SM A10616 Electric actuator ECR controller CC Link specification SM A10617 Electric actuator ECR controll...

Page 8: ...SM A14445 A 2 1 PRODUCT 3 2019 08 19 1 4 Model Number Indication 1 4 1 FLCR Series...

Page 9: ...SM A14445 A 2 1 PRODUCT 4 2019 08 19 1 4 2 Motor cable fixed movable 1 4 3 Encoder cable fixed movable...

Page 10: ...5 MR 116 3 Max load capacity 1 2 Horizontal kg 4 4 3 3 5 5 5 5 5 5 11 11 11 11 Vertical kg 4 4 0 5 0 5 6 6 0 8 0 8 8 5 8 5 3 3 Max pressing force N 90 20 150 55 210 90 Motor power supply voltage 48 24...

Page 11: ...nt capacity as a power supply for the controller and the input output circuit If the product is directly connected to an AC power supply a fire burst or damage may occur Do not work with wet hands An...

Page 12: ...shock may occur Do not connect the communication connector of the product to other devices A malfunction or damage may occur Make sure to install the emergency stop button in a location where operatio...

Page 13: ...d Remove all the FG frame ground connections of the product before performing electric welding on the device to which the product is installed If electric welding is performed without removing the FG...

Page 14: ...ature The customer is responsible for checking the compatibility of the product with the customer s system machinery and device Connect only cables designed for the product A failure of the product or...

Page 15: ...jected to twisting or bending force Before adjusting the gain firmly secure the actuator body to a rigid device and mount the jigs Do not hold the controller case tightly When using positioning holes...

Page 16: ...th dents The controller is set using setting software S Tools Leave a space of 70 mm or more in front of the controller so that the connector of the connection cable of the PC can be connected and dis...

Page 17: ...mm FLCR 16 M5 0 8 2 9 to 5 1 M6 1 0 4 8 to 8 6 9 FLCR 20 M5 0 8 2 9 to 5 1 M6 1 0 4 8 to 8 6 9 FLCR 25 M6 1 0 4 8 to 8 6 M8 1 5 12 0 to 21 6 12 2 3 2 Objects transferred slide table upper surface The...

Page 18: ...t Damage may occur When attaching a jig to the end plate observe the following values for the bolt screw in depth and the tightening torque Bolt Tightening torque N m Max screw in depth L mm FLCR 16 M...

Page 19: ...or off or malfunction and runaway due to the product becoming damaged may occur Take measures to prevent damage to the human body and the device in case of power failures An unexpected accident may oc...

Page 20: ...when the setting values are the same Do not turn off the servo while gravity or force of inertia is applied The movable section may continue to move or fall off if the servo is turned off Turn off th...

Page 21: ...ot apply excessive torque to the manual operation screw An operation fault or damage may occur The manual operation is mainly intended for use in starting maintenance and inspection If used too often...

Page 22: ...ient diameter that can allow the instantaneous maximum current to flow A heat generation or damage may occur during operation Perform periodic inspections two to three times a year to confirm that the...

Page 23: ...cracks on the cables Visual inspection Replace the cable 3 Check that foreign matters are not accumulating or are not stuck in the linear guide section Visual inspection Clean the parts Note 1 After c...

Page 24: ...ck the details of the alarm The details of the alarm can be checked with the setting software S Tools 5 Check the state of the I O The state of the I O can be checked with the setting software S Tools...

Page 25: ...t connection Wiring is not correct Refer to Chapter 4 in Controller Instruction Manual SM A10615 and check the wiring Product does not operate as intended with PLC signal Input signal is unstable Inpu...

Page 26: ...ioning completion output does not turn off Positioning completion output width is too large for movement distance Check the Positioning width in the point data Pressing operation cannot be performed M...

Page 27: ...ntrol of CKD The warranty stated herein covers only the delivered product itself Any loss or damage induced by failure of the delivered product is excluded from this warranty Confirmation of product c...