69
The 7400-5708 SHoW DMX Vero Net Transceiver Configuration Guide
Configuration
You can configure the Vero Net Transceiver’s basic operating settings using the System
Settings switches shown in the detail above.
Configuration switches:
P5, DMX Term: DMX512 termination On or Off. Turn On for end-of-line DMX512
connection
P4, Rx/Tx: Receiver (Rx) On, or Transmitter (Tx) Off. Selects Receiver or Transmitter
operation
P3, Reset: On or Off. Switch On to Reset
P2, Bootloader: On or Off. Sets the unit to Bootloader mode to upload and install Host
and radio firmware upgrades from a connected USB Memory device
P1, Default: On or Off. To restore the system to factory default settings:
1. Set P1 Default to On
2. Wait for PCBA LED to blink rapidly
3. Switch P1 to Off