- 15 -
Initial Settings
The initial settings are shown below.
Changes to the IP address, subnet mask and default gateway are performed using the
Web browser. For details on how to change the settings, see the section in this manual
on connecting via a web browser.
IP address
192.168.0.200
Subnet mask
255.255.255.0
Default gateway
0.0.0.0
Webpage User Name
admin
Webpage Password
admin
You can check the operating status of the time server and configure the SNMP settings
using the web browser (such as Internet Explorer) of a computer connected to the
network. SNMP (Simple Network Management Protocol) is a protocol for monitoring
devices on a network, and is useful for discovering operation errors in the time server.
○ Returning Settings to Default Values After Changing Settings
Remove all of the wires and then plug in the AC adapter of the signal converter to turn
the power on. Next, use a thin flat head screwdriver or pointed stick to press and hold
the initialization button for at least 5 seconds. Initialization is complete when the
reception monitor flashes quickly in orange. Release the initialization button.
Caution
When initializing the settings, be sure to first remove the AC
adapter to switch off the power before disconnecting all connected
cables to the device. Initializing with cables connected may result
in malfunction or damage.
Initialization button
Reception monitor