- 462 -
4.1.17 CT-E651
No.
Setting
OFF
ON
MSW1-1
Power ON Info
● Valid
Not send
MSW1-2
Buffer Size
● 4K bytes
45 bytes
MSW1-3
Busy Condition
● Full/Err
Full
MSW1-4
Receive Error
● Print ?
No Print
MSW1-5
CR mode
● Ignored
LF
MSW1-6
Reserved
● Fixed
-
MSW1-7
DSR Signal
● Invalid
Valid
MSW1-8
Init Signal
● Invalid
Valid
MSW2-1
Reserved
-
● Fixed
MSW2-2
Auto Cutter
Invalid
● Valid
MSW2-3
Spool Print
● Invalid
Valid
MSW2-4
Full Col Print
LineFeed
● WaitData
MSW2-5
Resume aft PE
● Next
Top
MSW2-6
Reserved
● Fixed
-
MSW2-7
Reserved
● Fixed
-
MSW2-8
PNE Sensor
● Valid
Invalid
MSW3-1
Resum Cttr Err
● Valid
Invalid
MSW3-2
PE signal by PNE
Valid
● Invalid
MSW3-4
Reserved
● Fixed
-
MSW3-5
Reserved
● Fixed
-
MSW3-6
Reserved
● Fixed
-
MSW3-7
CBM1000 Mode
● Invalid
Valid
MSW3-8
Resum Open Err
● Close
Command
MSW4-1
Reserved
● Fixed
-
MSW4-2
Reserved
● Fixed
-
MSW4-3
Feed&Cut at TOF
Invalid
● Valid
MSW4-4
Reserved
● Fixed
-
MSW4-5
Reserved
● Fixed
-
MSW4-6
Reserved
● Fixed
-
MSW4-7
Reserved
● Fixed
-
MSW4-8
Partial only
Invalid
● Valid
MSW5-1
Buzzer
● Valid
Invalid
MSW5-2
Line Pitch
● 360
406
MSW5-3
USB Mode
Virtual COM
● Printer Class
MSW5-4
Reserved
● Fixed
-
MSW5-5
Reserved
● Fixed
-
MSW5-6
Reserved
● Fixed
-
MSW5-7
Reserved
● Fixed
-
MSW5-8
Reserved
● Fixed
-
MSW6-1
Act. For Driver
● Invalid
Valid
MSW6-2
Character space
Invalid
● Valid
MSW6-3
USB Power Save
Invalid
● Valid
MSW6-4
Reserved
● Fixed
-
MSW6-5
Reserved
● Fixed
-
MSW6-6
Reserved
● Fixed
-
MSW6-7
Reserved
● Fixed
-
MSW6-8
Power On Trigger
● Power Switch ON
AC Power Input
●: Factory setting