2.2.9 Panel Switch Commands
ESC c 5 n
[Function]
Enabling/disabling the panel switches
[Code]
<1B>H<63>H<35>H<n>
[Range]
0
≤n≤255
[Outline]
[The specification which is common to the model]
• Enabling/disabling the FEED switch.
• “n” is valid only for the lowest bit (n0).
• Control by the lowest bit (n0) is shown as follows:
n0
Condition
0
FEED switch (LF-SW signal) valid
1
FEED switch (LF-SW signal) invalid
[Caution]
[The specification which is common to the model]
• When the FEED switch is disabled with this command, the paper cannot be fed by operating the
FEED switch.
• While switch operation is waited at the execution of macro, the FEED switch is always enabled regardless of
the setting of this command but no paper feed operation is carried out.
[Default]
n=0
CT-S801(II)
/
CT-S851(II)
• MSW3-2 OFF: n=0
• MSW3-2 ON : n=1
[Sample Program]
LPRINT CHR$(&H1B);"c5";CHR$(0); ----- When enabling the FEED switch
LPRINT CHR$(&H1B);"c5";CHR$(1); ----- When disabling the FEED switch