background image

C30STG

08/00

OWNER'S MANUAL

30 Lb. Stack Laundry Dryer

MODEL

GAS

C30STG

THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER.

THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER.

THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER.

THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER.

THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER.

CISSELL MANUFACTURING COMPANY

HEADQUARTERS

PHONE: (502) 587-1292

831 SOUTH FIRST ST.

SALES FAX: (502) 585-3625

P.O. BOX 32270

SERVICE/PARTS FAX:  (502) 681-1275

LOUISVILLE, KY  40232-2270

Summary of Contents for C30STG

Page 1: ...IVEN TO THE EQUIPMENT OWNER THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER CISSELLMANUFACTURINGCOMPA...

Page 2: ...l occupants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service mu...

Page 3: ...apparell __ QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d apparell Ne touchez a aucun interrupteur Ne pas vous servir des telephones se trouvant dans le batiment ou vous vous tro...

Page 4: ...s wrinkles from setting in and reduces the possibility of spontaneous combustion WARNING Be safe shut main electrical power and gas supply off externally before attempting service WARNING Never use dr...

Page 5: ...l to diagnose troubles to adjust remove or replace defective equipment or a part nor does it include any responsibility for transportation expense which is involved therein The warranty of Cissell is...

Page 6: ...ateExhaust 19 Dryer Make Up Air Requirements 20 ExhaustandVenting 21 Rules for Safe Operation 22 OperatingInstructions CoinMeter 23 24 Service Savers 25 Troubleshooting 26 29 SparkIgnitionSystem 30 31...

Page 7: ...en start demarrage Start arranquedeunmovimiento emission of heat in general mission de chaleur en general Warmeabgabeallgemein emisi ndecalor cooling refroidissement Kuhlen enfriamiento dangerousvolta...

Page 8: ...os dos sentidos directionofrotation sens de mouvement continu de rotation DrehbewegunginPfeilrichtung movimientogiratorioorotatorio en el sentido de la flecha End of Cycle caution attention Achtung at...

Page 9: ...motors Installation clearance from all combustable material is 0 ceiling clearance for the first 4 102 mm from the front of the dryer After the first 4 102 mm the ceiling clearance required is 6 153...

Page 10: ...Page 10 Outline Dimensions...

Page 11: ...cal h Natural or LP gases Gas Pressure 6 15 mbar 12 30 mbar WC input nat gas 3 5 8 7 mbar WC manifold press nat gas 10 5 26 2 mbar WC manifold press LP gas Gas Supply 1 2 NPT DN15 2 pipe connections E...

Page 12: ...quire the care that your laundry dryers now provide At the end of the drying cycle a timed cool down control automatically takes over and continues the rotation of the fan and basket without heat unti...

Page 13: ...necessary for the electrician to connect the power leads to the wire connectors within the service connection box on the rear of the dryer Do not change wiring without consulting factory as you may v...

Page 14: ...gas pressure inlet supply to dryer 10 5 inches water column 26 2 mbar maximum Manifold pressure 3 5 inches water column 8 8 mbar pressure 6 L P gas only check the gas pressure inlet supply to dryer 13...

Page 15: ...tem during any pressure testing of that system at test pressures in excess of 1 2 psi 3 5 kPa The dryer must be isolated from the gas supply piping system by closing it s individual manual shutoff val...

Page 16: ...nected upstream from the loop WARNING LIQUIFIEDPETROLEUMGASESONLY A gas pressure regulator for liquified petroleum gases is not furnished on the gas heated clothes dryers This regulator is normally fu...

Page 17: ...300000 330000 350000 380000 400000 430000 450000 480000 504000 550000 605000 650000 705000 750000 806000 850000 907000 960000 1000000 3 4 3 4 3 4 3 4 3 4 3 4 1 1 1 1 1 4 1 1 4 1 1 2 1 1 2 1 1 2 2 2 2...

Page 18: ...by a professional heating and air conditioner HVAC contractor Individual tumbler ducts should enter the main connector duct at a 45 angle in the direction of exhaust air flow The diameter of the main...

Page 19: ...Enclosure plenum with service door This separates the dryer air from the room comfort air If dryers use room air instead of outside air additional heat loss can be another 25 Btu h 6 3 kcal h for each...

Page 20: ...125 125 56 7 2000 3400 12 305 384 2477 C 150 150 68 2250 3825 12 305 432 2787 HD175 175 79 4 2780 4726 12 305 534 3445 HD190 190 86 2 3000 5100 12 305 576 3716 WMC HD20 20 9 1 450 765 6 153 87 561 WM...

Page 21: ...e installing an elbow on energy saver models only 5 Do not install wire mesh or other restrictions in the exhaust duct 6 Use clean outs in the exhaust duct and clean periodically when needed Examine t...

Page 22: ...warnings or precautions 7 Never tumble fiberglass materials in the dryer unless the labels say they are machine dryable Glass fibers break and can remain in the dryer and could cause skin irritation i...

Page 23: ...perature heavy fabrics and hard to dry cottons and linens MEDIUM 150 F 66 C exhaust temperature permanent press synthetic blends LOW 135 F 58 C exhaust temperature delicate sheer fabrics 4 Press the S...

Page 24: ...d for a capacity maximum load Overloading it will result in longer drying time and damp spots on some of the load Maximum operating efficiency depends on proper air flow The lint screen must be kept c...

Page 25: ...nedon 3 Check for low or intermittant gas pressure 4 Check spark ignition module diagnostic light CLOTHES ARE NOT SATISFACTORILY DRY 1 Timed cycle Did you allow enough heating time before the cool dow...

Page 26: ...eck with local power company for recommended corrective measures Check with local power company to insure that wiring is adequately sized for load Check all electrical connections and tighten any loos...

Page 27: ...cumulation or other causes that may prevent damper from opening Check duct work for lint build up Check installa tion sheet to insure that duct work and make up air openings are adequately sized Check...

Page 28: ...4 7 mm from burner opening Blow out Adjust gas pressure per rating plate Send to factory for correct orifices Clean exhaust Replace direct spark igniter Replace orifices Check factory for correct siz...

Page 29: ...if not Adjust gas pressure per rating plate Check service section for recommended sizes Remove obstructions or lint build up from duct work NEVER use smaller size exhaust duct ALWAYS use larger size...

Page 30: ...the module has multiple retries and no flame is detected the gas valve is de energized and the module goes into an interpurge delay After this delay the module will attempt another trial for the igni...

Page 31: ...Page 31 DIRECTSPARK IGNITIONOPERATION FLOW CHART...

Page 32: ...e for 10 years normal service After that bearings and housing should be cleaned and repacked one third full with Chevron grease No SR1 2 See label on motor for further information If motor overheats c...

Page 33: ...the shaft Step 4 Remove the nuts and washers holding the flange basket bearing and take it off the dryer Step 5 Inspect the bearings for damage and replace as necessary in reverse order of removing th...

Page 34: ...between the rim of the basket opening and the rim of the door opening in the positions shown in FIGURES 1 2 Check the two B pins for equal clearance NOTE Push the basket toward the rear Step 4 With t...

Page 35: ...ping the sweep sheet C Mark this position and the nearest rib to this position D Remove the basket do not loosen the alignment bolts E With the basket on the floor spider up place one or two shims bet...

Page 36: ...shown hold switch mounting bracket firmly and adjust switch actuator D with needle nose pliers at E by twisting actuator right or left whichever is needed so that switch closes when end of air blade...

Page 37: ...DEDASS Y 2 TUD0283 INSULATION TOP 3 TUD0375 COINCHUTE 4 TU7733 SCREW SELF TAP 5 TUD0258 SPRINGRETAINER 6 EA 00650 0 SWITCH LINTDRAWER 7 TUD0241 SWEEP SHEET LR TUD0239 SWEEP SHEET UR 8 TUD0240 SWEEP SH...

Page 38: ...Page 38 FRONTPANELASSEMBLY See next page...

Page 39: ...U7733 Screw 8 Self tapping 7 SB 00852 0 Washer star 8 CA 00699 0 Coin box bezel some models 9 ESA 00862 0 Reed switch 10 SB 00975 0 Screw 6 32 11 TUD0475WH Front panel Upper 12 SB 00836 0 Screw 10 pan...

Page 40: ...h pin 2 MD 00337 0 Magnet read switch 3 MD 00360 0 Gasket door rim gasket 4 SB 00852 0 Washer 1 4 external starluck 5 SB 00921 0 Screw 1 4 20 round head 6 TU15073 Door hinge spacer 7 TU15076 Door rim...

Page 41: ...1 0 LOCK AND KEY CONTROL 2 CA 00748 0 TRIM BOTTOMALM 3 TUD0234WH COVER PLT W A 4 SB 00951 0 SCREW 8 5 TU2853 LINTDRAWERGASKET 6 TUD00366 MAGNETSNAPCATCH 7 TU7858 LABEL INSTRUCTIONS 8 CA 00749 0 TOP TR...

Page 42: ...SB 00951 00 SCREW 8 2 TUD0256 MESH SCREEN 3 TUD0412 PLUG DOUBLE D NO LOCK 3A LA 00121 0 LOCK 4 TUD0279WH FRAME DRAWER NO LOCK 4A TUD00048WH FRAME DRAWER LOCKING 5 TUD0198 KICKPLATE 6 TUD0249WH COVER P...

Page 43: ...SS Y Ref Part No No Description 1 TUD0259 THERMOSTATBRACKET 2 TU7733 SELF TAP SCREW 3 SB 00952 0 SCREW 6 32 3 8 4 TU7733 SELF TAP SCREW 5 TU3400 NUT HEX 6 32 6 TU11991 THERMOSTAT CONTROL 7 TU3266 NUT...

Page 44: ...Part No No Description 1 M270 6 LOCK WASHER 2 TU12253 STUD 6 32 3 TU14404 CONTROL DMP 4 TU14451 OVERLAY UPPER TU14406 OVERLAY LOWER 5 TU3400 NUT 6 32 6 TUD0336 COIN DROP 7 TUD0367 5 40 NUT 8 TUD0452 A...

Page 45: ...art No No Description 1 M270 6 LOCK WASHER 2 TU12253 STUD 6 32 3 TU14404 DMP CONTROL 4 TU14405 OVERLAY 5 TU3400 NUT 6 32 6 TUD0458 LFT DMP PANEL UPPER TUD0459 RHT DMP PANEL LOWER PARTS TUMBLER ASSEMBL...

Page 46: ...der Asm Galv 1 TUS15068 Stainless steel basket assy 1 TU15068 Galvanized basket assy 2 TU15087 Spider assy 3 SB 00965 0 Screw button cap 5 16 18 4 TU7006 Shim 5 VSB130 Washer cut 5 16 6 TU2814 5 16 Lo...

Page 47: ...Page 47 PARTS TUMBLER ASSEMBLY REAR Ref Part No No Description 1 TUD0083 JACKETWELDEDASS Y 2 TU7733 SCREW SELF TAP 3 TUD0246 BELTGUARDCOVER...

Page 48: ...ASSEMBLY POWER TAP Ref Part No No Description 1 C1365 REGALCONNECTOR 2 SC517 J BOX 3 TU7733 SELF TAP SCREW 4 SC518 J BOX COVER 5 TU14958 TERMINALBLOCK 6 TU14959 TERM BLK END GRND 7 C170 BUSHING 8 CFA...

Page 49: ...UD0076 PULLEY 18 CAST IRON TU5446 PULLEY 18 PRESSED STEEL 2 TU10676 BEARING PILLOW BLOCK 3 OP251 WASHER 1 2 FLAT 4 TU2195 1 2 BOLT 5 OP233 NUT 1 2 6 TUD0411 BEARINGBOXASSY 7 RC347 CAP SCREW 1 2 13 8 T...

Page 50: ...124 WASHER 5 16 18 6 EA 00648 0 BRACKETCLIP 7 EA 00211 0 CONNECTOR 3 8 STRT 8 DA 00510 0 PULLEY 2 5 50HZ DA 00516 0 PULLEY 2 60HZ 9 DA 00428 0 MOTOR 1 2HP 115 230V 1PH DA 00447 0 MOTOR 1 2HP 220 380V...

Page 51: ...ription 1 CFA4000 CONDUIT 3 8 2 F876 CONNECTOR TOMICANGLE 3 C170 BUSHING 4 F888 E RING 5 TU2463 ACTUATORARM 6 TU3476 AIRSWITCHDECAL 7 TU1771 TINNERMAN NUT 6 8 TU8155 SWITCH 9 TU1770 INSULATOR 10 TU773...

Page 52: ...ATE 2 VSB130 5 16 WASHER 3 FB124 5 16 BOLT 4 TUD0171 BEARINGHOUSINGASS Y 5 DA 11711 0 SHAFT 6 TUD0187 KEY 7 DA 00530 0 PULLEY 2 5 8 TUD0196 AX34 BELT COG 9 DA 00531 0 9 PULLEY 10 DA 00522 0 AX62 BELT...

Page 53: ...REW SELF TAP 2 GA 00765 0 SPARK MODULE 24V US TU14675 SPARK MODULE 24V AUST GA 11007 0 SPARK MODULE 24 CE 3 GA 00803 0 HI VOLTCABLE 4 TU2372 SNAP BUSHING 5 TU2490 PLUG 6 TU15138 TRANSFORMER 120V 200 2...

Page 54: ...ECABLE 6 TU4934 NUT 1 4 20 7 TU2846 LOCK WASHER 1 4 8 TU2847 WASHER 1 4 9 CB36 HEX HD SCREW 1 4 20 10 TU3539 ORIFICE 11 GA 00774 0 PIPE MANIFOLD 12 TU14178 GASVALVENG TU14177 GASVALVELP 13 OP290 NIPPL...

Reviews: