Description
Color
LED
Network link state undefined.
Off
Network Status
(callout 1 on the chassis front
panel)
Network link state established on
at least one IFM, but no traffic
detected.
Solid Green
Network traffic detected on at least
one IFM.
Blinking Green
Chassis is in a degraded operational
state. For example:
• Power Supply Redundancy
Lost
• Mismatched Processors
• 1 on N Processors Faulty
• Memory RAS Failure
• Failed Storage Drive/SSD
Solid amber
System Status
(callout 1 on the chassis front
panel)
Normal operating condition.
Solid Green
Chassis is in a critical error state.
For example:
• Boot Failure
• Fatal Processor and/or bus
error detected
• Loss of both I/O Modules
• Over Temperature Condition
Blinking Amber
System is in an undefined
operational state or not receiving
power.
Off
No power to the chassis or the fan
module was removed from the
chassis.
Off
Fan Module
(callout 3 on the Chassis Rear
Panel)
Fan module restarting.
Amber
Normal operation.
Green
The fan module has failed.
Blinking amber
Cisco UCS X9508 Server Chassis Installation Guide
15
Overview
Interpreting LEDs
Summary of Contents for UCS X9508
Page 6: ...Cisco UCS X9508 Server Chassis Installation Guide vi Contents ...
Page 26: ...Cisco UCS X9508 Server Chassis Installation Guide 18 Overview Interpreting LEDs ...
Page 31: ...Cisco UCS X9508 Server Chassis Installation Guide 23 Installation Handling the Chassis ...
Page 64: ...Cisco UCS X9508 Server Chassis Installation Guide 56 Installation Repacking the Chassis ...
Page 124: ...Cisco UCS X9508 Server Chassis Installation Guide 116 Technical Specifications Switzerland ...