3-8
Cisco UCS S3260 Storage Server Chassis Installation and Service Guide
Chapter 3 Maintaining the System
Status LEDs and Buttons
Diagnostic LEDs in the Server Node
For the locations of the internal diagnostic LEDs inside the server node, see the service note for your
server node:
Cisco UCS C3X60 M3 Server Node For Cisco UCS S3260 System Service Note
Cisco UCS C3X60 M4 Server Node For Cisco UCS S3260 System Service Note
•
Cisco UCS S3260 M5 Server Node For Cisco UCS S3260 System Service Note
Table 3-4
Internal Diagnostic LED States
LED Name
State
1
SAS drive fault
•
Off—The drive is operating properly.
•
Amber—This drive has failed.
•
Amber, blinking—The device is rebuilding.
2
SAS drive activity
•
Off—There is no drive in the drive tray (no access, no fault).
•
Green—The drive is ready.
•
Green, blinking—The drive is reading or writing data.
3
Fan fault LEDs
•
Off—Component is functioning normally.
•
Amber—Component has failed.