background image

C

ISCO

 S

YSTEMS

P

UBLICATION

 H

ISTORY

 

170 W

EST

 T

ASMAN

 D

R

.

 

S

AN

 J

OSE

, CA, 95134

R

EV

 B.6

M

AY

 27, 2014

 

WWW

.

CISCO

.

COM

Spec Sheet

Cisco UCS C22 M3

High-Density Rack-Mount 

Server 

 

(Small Form Factor Hard 

Disk Drive Model)

Summary of Contents for UCS C22 M3

Page 1: ...ISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE CA 95134 REV B 6 MAY 27 2014 WWW CISCO COM Spec Sheet Cisco UCS C22 M3 High Density Rack Mount Server Small Form Factor Hard Disk Drive Model ...

Page 2: ...1 ORDER A TRUSTED PLATFORM MODULE 35 STEP 12 ORDER OPTIONAL USB 2 0 DRIVES 36 STEP 13 SELECT OPERATING SYSTEM AND VALUE ADDED SOFTWARE 37 STEP 14 SELECT OPERATING SYSTEM MEDIA KIT 40 STEP 15 SELECT SERVICE and SUPPORT LEVEL 41 OPTIONAL STEP ORDER RACK s 46 OPTIONAL STEP ORDER PDU 47 SUPPLEMENTAL MATERIAL 48 CHASSIS 48 CPUs and DIMMs 49 Physical Layout 49 Memory Population Rules 51 Recommended Memo...

Page 3: ...s Servers the Cisco UCS C22 M3 server and the Cisco 1225 VIC further extend the capabilities of the Cisco UCS portfolio in a 1RU form factor with the addition of the Intel Xeon E5 2400 v2 and E5 2400 series processor family CPUs which delivers the best combination of performance and efficiency gains In addition the Cisco UCS C22 M3 server offers 12 DIMM slots up to eight disk drives two PCIe slots...

Page 4: ...sis Front View 1 Power button power status LED 6 Power supply status LED 2 Identification button LED 7 Network link activity LED 3 System status LED 8 USB 2 0 ports two 4 Fan status LED 9 Pull out asset tag 5 Temperature status LED 10 Drives up to eight hot swappable 2 5 inch drives HDD06 HDD01 HDD07 HDD02 HDD08 HDD03 HDD04 HDD04 HDD04 HDD05 HDD05 HDD05 1 2 3 4 9 10 5 6 7 8 302158 ...

Page 5: ...profile PCIe slot on riser 2 PCIe Gen 3 slot x8 half height half length 7 VGA video port DB 15 connector 3 Slot 1 Standard profile PCIe slot on riser 1 PCIe Gen 3 slot x16 full height half length 8 10 100 1000 Base T Ethernet dedicated management port 4 Dual 1 Gb Base T Ethernet ports two 9 Rear Identification button LED 5 USB 2 0 ports four PSU 1 PSU 1 PSU 1 PCIe 2 PCIe 2 PCIe 2 PCIe 1 PCIe 1 PCI...

Page 6: ...U 1 Slot 1 PCIe Gen 3 slot x16 extended connector Cisco CNIC half length full height with NCSI1 and Cisco CNIC2 support The Cisco 1225 virtual interface card requires an NCSI slot Riser 2 controlled by CPU 2 Slot 2 PCIe Gen 3 slot x8 connector half length half height no NCSI support Internal storage devices Up to eight 2 5 inch SAS SATA hot swappable hard disk drives HDDs or solid state drives SSD...

Page 7: ...roller supporting RAID 0 1 and 10 and up to eight internal SAS SATA drives LSI MegaRAID 9220 4i RAID 4 port PCIe RAID controller supporting RAID 0 1 and 10 and up to four internal SAS SATA drives Interfaces Rear panel One DB9 serial port connector Four USB 2 0 port connectors One DB15 VGA connector One 10 100 1000 Ethernet management port Two 1 GbE 10 100 1000 Mbps capable Ethernet LOM ports Front...

Page 8: ...IMC Depending on your CIMC settings the CIMC can be accessed through the 1 Gb Ethernet dedicated management port the 1 Gb Ethernet LOM ports or a Cisco 1225 virtual interface card Notes 1 NCSI network communications services interface protocol The slot stays active when the server is in standby power state 2 CNIC Cisco network interface card Capability Feature Description ...

Page 9: ...6 SELECT PCIe OPTION CARD s page 24 STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES page 25 STEP 8 SELECT AC POWER CORD s page 30 STEP 9 ORDER POWER SUPPLY page 33 STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM page 34 STEP 11 ORDER A TRUSTED PLATFORM MODULE page 35 STEP 12 ORDER OPTIONAL USB 2 0 DRIVE page 36 STEP 13 SELECT OPERATING SYSTEM AND VALUE ADDED SOFTWARE page 37 STEP 14 SELECT O...

Page 10: ...t UCSC RAIL1 Does not include power supply CPU memory hard disk drives HDDs solid state drives SSDs or plug in PCIe cards Table 2 PID of the C22 M3 High Density SFF Rack Base Server Product ID PID Description UCSC C22 M3S UCS C22 M3 SFF with rail kit without PSU CPU memory HDD SSD or PCIe cards NOTE Use the steps on the following pages to configure the server with the components that you want to i...

Page 11: ...f CPU clock and DIMM clock Intel Xeon E5 2400 v2 UCS CPU E52470B E52470 v2 2 4 95 25 10 8 0 1600 UCS CPU E52450B E52450 v2 2 5 95 20 8 8 0 1600 UCS CPU E52440B E52440 v2 1 9 95 20 8 7 2 1600 UCS CPU E52430B E52430 v2 2 5 80 15 6 7 2 1600 UCS CPU E52430LB E52430L v2 2 4 60 15 6 7 2 1600 UCS CPU E52420B E52420 v2 2 2 80 15 6 7 2 1600 UCS CPU E52407B E52407 v2 2 4 80 10 4 6 4 1333 UCS CPU E52403B E52...

Page 12: ... one of the rows of Table 3 on page 11 Caveats You can select either one CPU or two identical CPUs If you select one CPU only one PCIe slot the full height slot on riser 1 is available for use For optimal performance select DIMMs with the highest clock speed for a given processor see Table 3 on page 11 If you select DIMMs whose speeds are lower or higher than that shown in the tables suboptimal pe...

Page 13: ... DIMMs Clock speed 1600 or 1333 MHz Ranks per DIMM 1 2 or 4 Operational voltage 1 35 V or 1 5 V Registered ECC DDR3 DIMMS RDIMMS unregistered DIMMs UDIMMs or load reduced DIMMs LRDIMMs Memory is organized with three memory channels per CPU with up to two DIMMs per channel as shown in Figure 4 Figure 4 C22 M3 SFF Memory Organization ...

Page 14: ...actly the same location on a DIMM and its mirrored DIMM Memory mirroring reduces the amount of memory available to the operating system by 50 because only one of the two populated channels provides data Table 4 Available DDR3 DIMMs Product ID PID PID Description Voltage Ranks DIMM DIMM Options UCS MR 1X041RY A 4GB DDR3 1600 MHz RDIMM PC3 12800 1R x4 1 35v 1 35 V 1 UCS MR 1X082RX A 8GB DDR3 1333 MH...

Page 15: ...tailed information 2 2 CPU configuration with memory mirroring Select 2 or 4 DIMMs per CPU 4 or 8 DIMMs total The DIMMs will be placed by the factory as shown in the following table Select the memory mirroring option N01 MMIRROR as shown in Table 4 on page 14 Number of DIMMs DIMM Placement in Channels Channel A is not used with memory mirroring 2 CPU 1 1 DIMM in Channel B 1 DIMM in Channel C 4 CPU...

Page 16: ...ult all DIMMs run at 1 35 V which yields 1333 MHz memory speeds To run the memory DIMMS at 1600 MHz you need to go into the BIOS or set the policy with UCSM service profile to run in Performance Mode This forces the DIMMs to operate at 1 5 V and yields 1600 MHz speeds provided The DIMMs are 1600 MHz devices The CPUs chosen support 1600 MHz operation For more information regarding memory see CPUs a...

Page 17: ...ontroller that supports up to four SATA only drives RAID 0 1 10 NOTE When creating a RAID volume follow these guidelines Use the same capacity for each drive in the volume Use either all SAS drives or all SATA drives Use either all HDDs or all SSDs NOTE The number of RAID groups virtual drives supported per controller is as follows note however that this server can have a maximum of only eight int...

Page 18: ...A drives can be mixed This option supports RAID 0 1 5 and 10 and operates at 3 Gb s Operating systems supported are Windows and Linux only no VMware support Table 6 Available Hardware RAID Options Product ID PID PID Description RAID Controllers Note that PCIe RAID controllers are installed by default in slot 1 for 1 CPU systems and slot 2 for 2 CPU systems UCSC RAID 9240 8I LSI MegaRAID 9240 8i Su...

Page 19: ...or embedded RAID R2XX RAID0 Factory preconfigured RAID striping option Enable RAID 0 Setting Requires a minimum of one hard drive R2XX RAID1 Factory preconfigured RAID mirroring option Enable RAID 1 Setting Requires exactly two drives with the same size speed capacity R2XX RAID5 Factory preconfigured RAID option Enable RAID 5 Setting Requires a minimum of three drives of the same size speed capaci...

Page 20: ...CPU configurations PCIe slot 1 is the default slot supported for an internal drive RAID controller PCIe slot 2 is not supported for 1 CPU systems NOTE If you do not select a PCIe RAID controller or one of the embedded RAID upgrade options from Table 5 on page 18 you will have an embedded SATA only RAID controller that supports up to four SATA only drives RAID 0 1 10 and slot 1 can be used for a PC...

Page 21: ...lers are all half height If you choose one of these cards in a 2 CPU configuration only the full height PCIe card slot will be available for an additional optional PCIe card Note that only a single Cisco UCS 1225 Virtual Interface Card VIC card is supported and it must be installed in the full length full height PCIe slot slot 1 on riser 1 which is the only slot that supports NCSI So take this int...

Page 22: ...F SAS 300 GB A03 D500GC3 500 GB SATA 7 2K RPM SFF SATA 500 GB A03 D600GA2 600 GB 6Gb SAS 10K RPM SFF SAS 600 GB UCS HDD900GI2F106 900 GB 6Gb SAS 10K RPM SFF SAS 600 GB A03 D1TBSATA 1 TB SATA 7 2K RPM SFF SATA 1 TB SSDs UCS SD200G0KS2 EP 200 GB 2 5 inch Enterprise Performance SAS SAS 200 GB UCS SD400G0KS2 EP 400 GB 2 5 inch Enterprise Performance SAS SAS 400 GB UCS SD800G0KS2 EP 800 GB 2 5 inch Ent...

Page 23: ... RAID or a PCIe RAID controller you can only select up to four SATA drives which will be controlled by the embedded SATA only RAID controller Caveats You can mix SATA and SAS drives If you select one or more SAS drives you must select either a PCIe RAID controller from Table 6 on page 18 or an embedded RAID option from Table 5 on page 18 If you select four or less SATA only drives you can select a...

Page 24: ...com 5709 Dual Port Ethernet PCIe Adapter w TOE for M3 Servers Half N2XX ABPCI03 M3 Broadcom 5709 Quad Port 10 100 1Gb NIC w TOE iSCSI for M3 Servers Half UCSC PCIE BTG Broadcom 57712 Dual Port 10GbE 10G BaseT w TOE Half N2XX AIPCI01 Intel 10GbE 2 Port Niantec Controller with Copper SFP Cable Half UCSC PCIE IRJ45 Intel Quad Port GbE controller this is a quad port i350 controller Half UCSC PCIE ITG ...

Page 25: ...ports NCSI Additional considerations for the Cisco 1225 VIC card Supports 10G SFP optical and copper twinax connections The server supports installation of only one Cisco VIC 1225 card and it is supported only in PCIe slot 1 Slot 1 can operate while the server is in standby power mode Requires that the server has CIMC firmware version 1 4 6 or later installed There is a heartbeat LED on the top of...

Page 26: ...hoose one or two twinax cables for each compatible PCIe network card ordered The cables can be different lengths however you would normally order two cables of equal lengths to connect to the primary and redundant network switching equipment Choose Optional SFP Modules Optical Cisco SFP modules are listed in Table 10 Table 9 Available Twinax Cables Product ID PID PID Description SFP H10GB CU1M 10G...

Page 27: ...atible PCIe network card ordered You would normally order two modules for connecting to the primary and redundant network switching equipment With the SFP optical modules you can use common fiber optic cables widely available See Figure 5 on page 29 for typical SFP and twinax connections to the network cards Caveats Check the table on the following page for compatibility between the PCIe network c...

Page 28: ...Yes Yes No UCSC PCIE Q8362 Qlogic QLE8362 dual port 10 GbE FCoE CNA Yes Use Qlogic SFP UCSC PCIE E14102 Emulex OCe14102 UX dual port 10 GbE FCoE CNA Yes Yes No Network Interface Cards NICs N2XX ABPCI01 M3 Broadcom 5709 Dual Port Ethernet PCIe Adapter for M3 Servers Yes No No N2XX ABPCI03 M3 Broadcom 5709 Quad Port 10 100 1Gb NIC w TOE iSCSI for M3 Servers Use RJ45 Ethernet cable N2XX AIPCI01 Intel...

Page 29: ... SFP UCSC PCIE Q2672 Qlogic QLE2672 CSC 16Gb Fibre Channel HBA with SR Optics No Preinstalled do not change SFP UCSC PCIE E16002 Emulex LPe16002 M6 16Gb Fibre Channel HBA with SR Optics No Preinstalled do not change SFP Notes 1 This card supports a 4x10 Gbps QSFP to SFP breakout fiber cable Table 11 PCIe Card Compatibility continued PCIe Cards Twinax Cables Cisco SFP Modules SFP 10G SR DS SFP FC8G...

Page 30: ...lable Power Cords Product ID PID PID Description Images R2XX DMYMPWRCORD No power cord dummy PID to allow for a no power cord option Not applicable CAB N5K6A NA Power Cord 200 240V 6A North America CAB AC L620 C13 AC Power Cord NEMA L6 20 C13 2M 6 5ft CAB C13 CBN CABASY WIRE JUMPER CORD 27 L C13 C14 10A 250V CAB C13 C14 2M CABASY WIRE JUMPER CORD PWR 2 Meter C13 C14 10A 250V CAB C13 C14 AC CORD PW...

Page 31: ...ords Product ID PID PID Description Images 186571 2500 mm Cordset rating 10 A 250 500 V MAX Length 8 2 ft Plug EL 219 IRAM 2073 Connector EL 701 IEC60320 C13 Plug Cordset rating 10 A 250 V 500 V MAX Length 2500mm 186580 Connector EL 701C EN 60320 C15 EL 210 BS 1363A 13 AMP fuse Cordset rating 10A 250V 2500 mm Plug EL 218 CCEE GB2009 186573 Connector EL 701 IEC60320 C13 Connector VSCC15 Cordset rat...

Page 32: ...zil CAB JPN 3PIN Power Cord 3PIN Japan Image not available Table 12 Available Power Cords Product ID PID PID Description Images Plug I 3G CEI 23 16 Connector C15M EN60320 C15 Cordset rating 10 A 250 V Length 8 ft 2 in 2 5 m 186575 Plug MP232 R Cordset rating 10 A 250 V Length 8 ft 2 in 2 5 m 186578 Connector IEC 60320 C15 Plug Cordset rating 10 A 250 V 500 V MAX Length 2500mm 186580 Connector EL 7...

Page 33: ...pply see Table 13 Prior to making a power supply selection the UCS Power Calculator should be run to determine the right size power supply for your server configuration A fully configured C22 M3 server may require the 650 W power supply The UCS Power Calculator can be found at the following link https express salire com Go Cisco Cisco UCS Power Calculator aspx Table 13 Power Supply PIDs Product ID...

Page 34: ...management Use Table 14 to order a cable management arm For more information about the cable management arm see the Cisco UCS C22 M3 Installation and Service Guide at this URL http www cisco com en US docs unified_computing ucs c hw C22 install C22 pdf Table 14 Cable Management Arm Product ID PID PID Description UCSC CMA1 Cable Management Arm for C22 rack servers NOTE If you order and install a ca...

Page 35: ...asurements that help ensure that the platform remains trustworthy Authentication ensuring that the platform can prove that it is what it claims to be and attestation a process helping to prove that a platform is trustworthy and has not been breached are necessary steps to ensure safer computing in all environments The TPM ordering information is listed in Table 15 Table 15 Trusted Platform Module ...

Page 36: ...can accommodate the 8 GB drive The 8 GB drive if ordered is blank and comes installed on the motherboard It can be used for a hypervisor or a license dongle The USB drive ordering information is listed in Table 16 See Figure 6 on page 48 for the location of the internal USB connector Table 16 USB 2 0 Drive Product ID PID PID Description UCS USBFLSHA 8GB 8 GB Flash USB Drive for C22 C24 ...

Page 37: ...x Enterprise Srvr 1 2 CPU 1 Phys 5yr Support Reqd SLES SVR 2S UG 1A SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt 1yr Support Reqd SLES SVR 2S UG 3A SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt 3yr Support Reqd SLES SVR 2S UG 5A SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt 5yr Support Reqd SLES SHA 2S 1A SUSE Linux High Availability Ext 1 2 CPU 1yr Support Reqd SLES SHA 2S 3A SUSE Linux High Availability Ex...

Page 38: ... Server BMC SE 4C BMC BladeLogic Standard Edition 4 Cores Support Required BMC SE 6C BMC BladeLogic Standard Edition 6 Cores Support Required BMC SE 8C BMC BladeLogic Standard Edition 8 Cores Support Required BMC SE 10C BMC BladeLogic Standard Edition 10 Cores Support Required BMC AE 4C BMC BladeLogic Advanced Edition 4 Cores Support Required BMC AE 6C BMC BladeLogic Advanced Edition 6 Cores Suppo...

Page 39: ...are vSphere 5 Enterprise for 1 CPU 5 Yr Support Rqd VMW VS5 ENTP 1A VMware vSphere 5 Enterprise Plus for 1 Processor 1 Year Support Rqd VMW VS5 ENTP 2A VMware vSphere 5 Enterprise Plus for 1 CPU 2 Yr Support Rqd VMW VS5 ENTP 3A VMware vSphere 5 Enterprise Plus for 1 Processor 3 Year Support Rqd VMW VS5 ENTP 4A VMware vSphere 5 Enterprise Plus for 1 Processor 4 Year Support Rqd VMW VS5 ENTP 5A VMwa...

Page 40: ...scription RHEL 6 RHEL 6 Recovery Media Only Multilingual SLES 11 SLES 11 media only multilingual MSWS 08R2 STHV RM Windows Svr 2008 R2 ST 1 4CPU 5CAL Media MSWS 08R2 ENHV RM Windows Svr 2008 R2 EN 1 8CPU 25CAL Media MSWS 08R2 DCHV RM Windows Svr 2008 R2 DC 1 8CPU 25CAL Media MSWS 12 ST2S RM Windows Server 2012 Standard 2 CPU 2 VMs Recovery Media MSWS 12 DC2S RM Windows Server 2012 Datacenter 2 CPU...

Page 41: ...ified computing environment Access to Cisco Technical Assistance Center TAC is provided around the clock from anywhere in the world For UCS blade servers there is Smart Call Home which provides proactive embedded diagnostics and real time alerts For systems that include Unified Computing System Manager the support service includes downloads of UCSM upgrades The Cisco SMARTnet for UCS Service inclu...

Page 42: ... PSS provides partners with access to Cisco s support infrastructure and assets to help them Expand their service portfolios to support the most complex network environments Lower delivery costs Deliver services that increase customer loyalty Partner Unified Computing Support Options enable eligible Cisco partners to develop and consistently deliver high value technical support that capitalizes on...

Page 43: ...o Optimize the uptime performance and efficiency of your UCS Protect your vital business applications by rapidly identifying and addressing issues Strengthen in house expertise through knowledge transfer and mentoring Improve operational efficiency by allowing UCS experts to augment your internal staff resources Enhance business agility by diagnosing potential issues before they affect your operat...

Page 44: ...ompany has a need to control confidential classified sensitive or proprietary data you might want to consider one of the Drive Retention Services listed in Table 24 Table 23 UCS Computing Combined Support Service Product ID PID Service Level GSP On Site Description CON NCF2 C22M3S NCF2 No CMB SPT SVC 24X7X2 UCS C22 M3 Server SFF CON NCF2P C22M3S NCF2P Yes CMB SPT SVC 24X7X2OS UCS C22 M3 Server SFF...

Page 45: ...w pdf For a complete listing of available services for Cisco Unified Computing System see this URL http www cisco com en US products ps10312 serv_group_home html SMARTnet for UCS HW ONLY Drive Retention UCS HW DR UCWD7 24x7x4 Onsite CON UCWD7 C22M3S UCWD5 8x5xNBD Onsite CON UCWD5 C22M3S Table 24 Drive Retention Service Options continued Service Description Service Program Name Service Level GSP Se...

Page 46: ... more information about the R42610 rack see RACKS page 57 Table 25 Racks and Rack Options Product ID PID PID Description RACK UCS1 Notes 1 Use these same base PIDs to order spare racks available only as next day replacements Cisco R42610 expansion rack no side panels RACK UCS21 Cisco R42610 standard rack w side panels RACK BLANK 001 Filler panels qty 12 1U plastic toolless RACK CBLMGT 001 Cable mg...

Page 47: ...ional power distribution unit PDU is available from Cisco for the C Series rack servers including theC22 M3 server This PDU is available in a zero rack unit RU style see Table 25 For more information about the PDU see PDUs page 59 Table 26 PDU Options Product ID PID PID Description RP208 30 2P U 2 Zero RU PDU ...

Page 48: ... Off 1 Drives hot swappable accessed through front panel 9 RTC battery on motherboard 2 Front panel operations board 10 PCIe riser 2 PCIe slot 2 3 Drive backplane 11 Trusted platform module socket on motherboard not visible under PCIe riser 2 4 Cooling fans five 12 Power supply accessed through rear panel PCIe 1 PCIe 2 SYS FAN1 SYS FAN2 SYS FAN3 SYS FAN4 CPU 1 CPU 2 SYS FAN5 285200 PSU 1 1 2 3 5 7...

Page 49: ...ks and channels are physically laid out on the motherboard The DIMM slots on the top channels A B and C are associated with CPU 1 while the DIMM slots on the bottom channels D E and F are associated with CPU 2 Bank 1 slots blue are populated before Bank 2 slots black 5 DIMM slots on motherboard 12 13 Integrated SAS RAID connectors on motherboard left to right SCU_Port 0 SCU_Port 1 6 CPU and heatsi...

Page 50: ...Cisco UCS C22 M3 High Density SFF Rack Mount Server 50 SUPPLEMENTAL MATERIAL Figure 7 Physical Layout of CPU DIMM Channels and Banks 285209 A1 A2 B1 B2 C1 C2 D1 D2 E1 E2 F1 F2 Front of Server CPU1 CPU2 ...

Page 51: ...els per CPU socket and 2 CPUs must be populated At 1 DPC and 2 DPC 1600 MHz DIMMS will run at 1600 MHz provided the CPU supports 1600 MHz DIMMs and 1333 MHz DIMMs will run at 1333 MHz When mixing DIMMs the following rules need to be followed When mixing DIMMs of different densities sizes populate DIMMs with the highest density first For example if you have to mix 16 GB with 8 GB DIMMs populate 16 ...

Page 52: ...m beyond 48 GB by going to 2 DPC while still maintaining memory speed at 1600 MHz If there is no plan to increase total memory size in the system beyond 48 GB then 12 x 4GB is more price effective at this time 3 x 4 GB 3 x 4 GB 3 x 4 GB 3 x 4 GB 12 3 x 8 GB 3 x 8 GB 6 72 GB 3 x 8 GB 3 x 4 GB 3 x 8 GB 3 x 4 GB 12 96 GB2 2 For 96 GB there are two possible optimal configurations 6 x 16GB occupies 1 D...

Page 53: ...20 GB 10 40 GB 6 x 4 GB 6 24GB 6 x 4 GB 6 24GB 12 48 GB 3 x 8 GB 3 24 GB 3 x 8 GB 3 24 GB 6 48 GB 4 x 8 GB 4 32 GB 4 x 8 GB 4 32 GB 8 64 GB 2 x 16 GB 2 32 GB 2 x 16 GB 2 32 GB 4 64 GB 3 x 8 GB 3 x 4 GB1 Notes 1 UCS MR 1X082RY A UCS MR 1X041RY A 6 36 GB 3 x 8 GB 3 x 4 GB2 2 UCS MR 1X082RY A UCS MR 1X041RY A 6 36 GB 12 72 GB 5 x 8 GB 5 40 GB 5 x 8 GB 5 40 GB 10 80 GB 6 x 8 GB 6 48 GB 6 x 8 GB 6 48 G...

Page 54: ...ntical manufacturer type speed and size Low voltage DIMMs and standard voltage DIMMs can be mixed in the same server Note that this causes the system BIOS to default to standard voltage operation Performance Mode That is the server cannot operate in Power Saving Mode unless all DIMMs are low voltage DIMMs CPUs that have a maximum memory frequency less than 1333 MHz support low voltage DIMMs operat...

Page 55: ...he 9270CV 8i 9240 8i 9220 8i or 9220 4i MegaRAID PCIe cards you can leave the cards installed Just disable the OPROM for their slots and the system will boot even with the cards installed Internal PCIe RAID 2 Drives Supported PCIe Slots2 2 A available slot O occupied slot U unsupported slot slot 2 is not supported in 1 CPU systems 1 2 C22 M3 SFF 1 Not allowed Installed slot 1 default 3 3 The OPROM...

Page 56: ... OPROM for the PCIe slots The server has a finite amount of option ROM with which it can boot up devices Go into the BIOS and disable the OPROM on the PCIe slots not used for booting so that resources are available for the slots that are used for booting An example OPROM BIOS screen is shown in Figure 8 Figure 8 Example BIOS Screen for OPROM ...

Page 57: ...s Parameter Standard Rack Expansion Rack Dimensions H x W x D 78 74 x 24 x 43 38 in 2000 x 610 x 1102 mm 78 74 x 23 58 x 43 38 in 2000 x 599 x 1102 mm Dimensions H x W x D with packaging 89 x 33 x 47 in 2261 x 838 x 1194 mm 89 x 33 x 47 in 2261 x 838 x 1194 mm Distance from front mounting rail to rear mounting rail 29 2 in 741 mm 29 2 in 741 mm Weight 299 83 lb 136 kg 231 49 lb 105 kg Weight with ...

Page 58: ...Cisco UCS C22 M3 High Density SFF Rack Mount Server 58 SUPPLEMENTAL MATERIAL Figure 9 Cisco R42610 Rack Front view door closed Front view door open Front view door removed ...

Page 59: ...ack you can replace up to two dozen input power cords with just one The fixed input cord connects to the power source from overhead or under floor distribution Your IT equipment is then powered by PDU outlets in the rack using short easy to manage power cords The C series severs accept the zero rack unit 0RU PDU See Figure 10 Figure 10 Zero Rack Unit PDU PID RP208 30 2P U 2 Cisco RP Series PDU mod...

Page 60: ...AL Motherboard USB Port The C22 M3 SFF motherboard has one general purpose USB socket as shown in Figure 11 Figure 11 Motherboard USB Port 1 Internal USB 2 0 port on motherboard under PCIe riser 1 PCIe 1 PCIe 2 SYS FAN1 SYS FAN2 SYS FAN3 SYS FAN4 CPU 1 CPU 2 SYS FAN5 PSU 1 1 ...

Page 61: ... 2 Identification button LED 7 Network link activity LED 3 System status LED 8 Hard drive fault LED 4 Fan status LED 9 Hard drive activity LED 5 Temperature status LED Table 31 Front Panel LEDs LED LED State Meaning Power LED is integrated into power button Off Server power is off On amber Server power is soft off power is supplied only to the CIMC and some motherboard functions On green Card powe...

Page 62: ...egraded operational state indicating that one of the fans has a fault Blinking amber Critical fault state indicating that two or more fans have a fault Temperature Status Off Undefined On green System is operating at normal temperature and no error conditions have been detected On amber One or more temperature sensors exceeded a warning threshold Blinking amber One or more temperature sensors exce...

Page 63: ...d Drive Activity Off There is no hard drive in the hard drive sled no access no fault On green The hard drive is ready Blinking green The hard drive is reading or writing data 1 Power supply fault LED 5 10 100 1000 Ethernet dedicated management link status LED 2 Power supply AC OK LED 6 10 100 1000 Ethernet dedicated management link speed LED 3 1 Gb Ethernet link speed LED 7 Rear Identification bu...

Page 64: ...condition Power Supply AC Off There is no AC power to the power supply Blinking green AC power OK DC output not enabled On green AC power OK DC outputs OK 1GbE Link Speed Off Link Speed 10 Mbps On amber Link Speed 100 Mbps On green Link Speed 1 Gbps 1GbE Link Status Off No Link On green Link is active Blinking green Traffic is present on the active link 10 100 1000 Base T Link Status Off No Link O...

Page 65: ...33 mm Weight Maximum 8 HDDs 2 CPUs 12 DIMMs 1 power supply 27 78 lbs 12 6 kg Bare 0 HDD 0 CPU 0 DIMM no power supply 23 48 lbs 10 65 kg Table 34 UCS C22 M3 SFF 450 W Power Supply Specifications Description Specification AC input voltage 90 to 264 VAC self ranging 100 to 120 VAC nominal 200 to 240 VAC nominal AC input frequency Range 47 to 63 Hz single phase 50 to 60 Hz nominal Maximum AC input cur...

Page 66: ...ower inlet Table 35 UCS C22 M3 SFF 650 W Power Supply Specifications Description Specification AC input voltage 90 to 264 VAC self ranging 100 to 120 VAC nominal 200 to 240 VAC nominal AC input frequency Range 47 to 63 Hz single phase 50 to 60 Hz nominal Maximum AC input current 7 6 A maximum at 100 VAC 3 65 A maximum at 208 VAC Maximum AC inrush current 11 A peak 35 C 208 VAC Maximum output power...

Page 67: ...5 to 35 C Maximum temperature is to be derated by 1 degree C for every 305 m 1000 ft of altitude above sea level Temperature nonoperating 40 to 149 F 40 to 65 C Humidity RH nonoperating non condensing 10 to 90 Altitude operating 0 to 3 000 m 0 to 10 000 ft Altitude nonoperating 0 to 12 192 m 0 to 40 000 ft Sound Power level Measure A weighted per ISO7779 LWAd Bels Operation at 73 F 23 C 5 9 Sound ...

Page 68: ...tory Compliance Products should comply with CE Markings per directives 2004 108 EC and 2006 95 EC Safety UL 60950 1 Second Edition CAN CSA C22 2 No 60950 1 Second Edition EN 60950 1 Second Edition IEC 60950 1 Second Edition AS NZS 60950 1 GB4943 2001 EMC Emissions 47CFR Part 15 CFR 47 Class A AS NZS CISPR22 Class A CISPR22 Class A EN55022 Class A ICES003 Class A VCCI Class A EN61000 3 2 EN61000 3 ...

Reviews: