51.3 show rmon alarm
To display alarm configuration, use the show rmon alarm Privileged EXEC mode
command.
Syntax
show rmon alarm
number
Parameters
alarm
number
—Specifies the alarm index. (Range: 1–65535)
Command Mode
Privileged EXEC mode
Example
The following example displays RMON 1 alarms.
switchxxxxxx#
show rmon alarm
1
Alarm 1
-------
OID: 1.3.6.1.2.1.2.2.1.10.1
Last sample Value: 878128
Interval: 30
Sample Type: delta
Startup Alarm: rising
Rising Threshold: 8700000
Falling Threshold: 78
Rising Event: 1
Falling Event: 1
Owner: CLI