B-9
Cisco ONS 15600 SDH Reference Manual, Release 9.0
78-18400-01
Appendix B Administrative and Service States
B.3.3 Pluggable Equipment Service State Transitions
Note
Pluggable equipment (pluggable interface modules [PIMs] and pluggable port modules [PPMs]) will
transition out of the unassigned state when inserted if the software can read the EEPROM and identify
information on the pluggable equipment. If the software cannot read the pluggable equipment, the
equipment is considered invalid and will not transition out of the unassigned state.
Table B-6
ONS 15600 SDH Pluggable Equipment Service State Transitions
Current Service State
Action
Next Service State
Unlocked-enabled
Reset the pluggable equipment.
Unlocked-enabled
Provision an unsupported service
rate.
Unlocked-disabled,mismatchOfEquipment
Pluggable equipment does not
work with the board configuration.
Unlocked-disabled,automaticInService &
notInstalled
Insert valid pluggable equipment.
Unlocked-enabled
Insert pluggable equipment with
the incorrect rate.
Unlocked-disabled,mismatchOfEquipment
Pluggable equipment does not
work with the board configuration.
Locked-disabled,mismatchOfEquipment
Delete unsupported service rate or
modify provisioning so that the
pluggable equipment is no longer a
mismatch.
Unlocked-enabled
Locked-disabled,notInstalled
Insert valid pluggable equipment.
Unlocked-enabled
Locked-disabled,mismatchOfEquipment &
maintenance
Delete unsupported service rate or
modify provisioning so that the
pluggable equipment is no longer a
mismatch.
Locked-enabled,maintenance
Locked-disabled,maintenance &
notInstalled
Insert valid pluggable equipment.
Locked-enabled,maintenance
Locked-disabled,unassigned
Provision valid pluggable
equipment.
Unlocked-enabled
Locked-disabled,unassigned &
notInstalled
Insert valid pluggable equipment.
Unlocked-enabled
Insert pluggable equipment with
the incorrect rate.
Unlocked-disabled,mismatchOfEquipment
Pluggable equipment does not
work with the board configuration.
Locked-enabled,maintenance
Reset the pluggable equipment.
Locked-enabled,maintenance
Provision an unsupported service
rate.
Locked-disabled,mismatchOfEquipment &
maintenance
Pluggable equipment does not
work with the board configuration.