Cisco ONS 15600 SDH Reference Manual, Release 9.0
78-18400-01
Chapter 13 SNMP
13.7 SNMP Trap Content
Note
If you cannot compile the proprietary MIBs correctly, log into the Cisco Technical Assistance Center
(TAC) at http://www.cisco.com/techsupport or call Cisco TAC (800) 553-2447.
13.7 SNMP Trap Content
The ONS 15600 SDH uses SNMP traps to generate all alarms and events, such as raises and clears. The
traps contain the following information:
•
Object IDs that uniquely identify each event with information about the generating entity (the slot
or port; virtual container [VC], or MS-SPRing).
•
Severity and service effect of the alarm (Critical [CR], Major [MJ], Minor [MN], or event;
Service-Affecting [SA] or Non Service Affecting [NSA]).
•
Date and time stamp showing when the alarm occurred.