4-42
Cisco ONS 15501 User Guide
78-14134-01, Release 1.0
Chapter 4 Command Reference
setoutsigpwrtrig
setoutsigpwrtrig
To set the output signal alarm trigger level, use the setoutsigpwrtrig command.
setoutsigpwrtrig trigger
Syntax Description
Defaults
20.00 dBm
Command Types
Changes configuration
Command Modes
Master password protected
Command History
Usage Guidelines
The output signal alarm trigger is measured in dB. The system accepts a minimum value of 0.5 dB and
a maximum value of 40 dB. If a value entered falls outside of this acceptable range, the command will
be ignored and have no effect.
Examples
The following example shows how to set the output signal alarm trigger level.
edfa > setoutsigpwrtrig 18.00
Related Commands
trigger
Specifies the desired output signal alarm trigger level.
Release
Modification
EDFA 1.0
This command was introduced.
Command
Description
Displays the calculated output signal power.
Displays the output signal alarm mean level.
Displays the output signal alarm trigger level.
Resets the signal gain and alarm mean level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, internal case temperature
alarm mean level, and internal case temperature alarm trigger level to the
manufacturer’s default settings.
Sets the output signal alarm mean level.