Figure 177: Dimension on Cisco ONS 15454 M6 relative to the air plenum
Air Plenum Rack and Cabinet Compatibility
The table shows the compatibility of air plenum with the ANSI and ETSI racks and cabinets. The chassis can
be installed with brackets in front position only.
Table 32: Air plenum compatibility with racks and cabinets
Front-to-back air flow
Rack / Cabinet
Supported
ANSI 19-inch rack
Supported
ANSI 19-inch cabinet
Supported
ANSI 23-inch rack
Supported
ANSI 23-inch cabinet
Supported
ETSI cabinet
A minimum opening of 20.600 inches is required to install the vertical air plenum behind the front rails.
The ANSI 19-inch two post rack that is compatible with air plenum installation is available from Telect, with
part number 12545-301.
Note
Cisco ONS 15454 Hardware Installation Guide
278
Installing the ONS 15454 M6 Shelf
Air Plenum Rack and Cabinet Compatibility