Chapter 22 DLPs A500 to A599
DLP-A522 Suppress Alarm Reporting
Figure 22-8
Alarm Filter Dialog Box Conditions Tab
When filtering is enabled, conditions in the Show list are visible and conditions in the Hide list are
invisible.
•
To move conditions individually from the Show list to the Hide list, click the
>
button.
•
To move conditions individually from the Hide list to the Show list, click the
<
button.
•
To move conditions collectively from the Show list to the Hide list, click the
>>
button.
•
To move conditions collectively from the Hide list to the Show list, click the
<<
button.
Note
Conditions include alarms.
Step 6
Click
Apply
and
OK
.
Alarm and condition filtering parameters are enforced when alarm filtering is enabled (see the
“DLP-A225 Enable Alarm Filtering” task on page 19-17
), and are not enforced when alarm filtering is
disabled (see the
“DLP-A227 Disable Alarm Filtering” task on page 19-17
).
Step 7
Return to your originating procedure (NTP).
DLP-A522 Suppress Alarm Reporting
Purpose
This task suppresses the reporting of ONS 15454 alarms at the node, card,
or port level.
Tools/Equipment
None
Prerequisite Procedures
DLP-A60 Log into CTC, page 17-66
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Summary of Contents for ONS 15454 Series
Page 28: ...Tables xxviii Cisco ONS 15454 Procedure Guide R5 0 December 2004 ...
Page 44: ...Tasks xliv Cisco ONS 15454 Procedure Guide R5 0 December 2004 ...
Page 53: ...liii Cisco ONS 15454 Procedure Guide R5 0 December 2004 About this Guide Document Conventions ...
Page 55: ...lv Cisco ONS 15454 Procedure Guide R5 0 December 2004 About this Guide Document Conventions ...
Page 850: ...Index IN 22 Cisco ONS 15454 Procedure Guide R5 0 December 2004 description 4 11 remove 18 23 ...