DLP-A208 Change External Alarms Using the AIC-I Card
Figure 19-1
Installing Fiber-Optic Cables
Step 4
Return to your originating procedure (NTP).
DLP-A208 Change External Alarms Using the AIC-I Card
Note
The procedure is the same if you are using the alarm expansion panel (AEP). In this case, the number of
contacts that are shown on the screen is changed accordingly.
Step 1
Confirm that external-device relays are wired to the ENVIR ALARMS IN backplane pins. See the
“DLP-A19 Install Alarm Wires on the Backplane” task on page 17-22
for more information.
Step 2
Double-click the AIC-I card to display it in card view.
Step 3
Click the
Provisioning > External Alarms
tabs.
Step 4
Modify any of the following fields for each external device wired to the ONS 15454 backplane. For
definitions of these fields, see the
“NTP-A258 Provision External Alarms and Controls on the Alarm
Interface Controller-International” procedure on page 7-11
•
Enabled
•
Alarm Type
•
Severity
•
Virtual Wire
•
Raised When
•
Description
Purpose
This task changes external alarm settings on the Alarm Interface
Controller–International (AIC-I) card.
Tools/Equipment
None
Prerequisite Procedures
DLP-A60 Log into CTC, page 17-66
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Tx
Rx
FAIL
ACT
SF
32082
Front edge of card
SC cable connector
SC faceplate connector
Summary of Contents for ONS 15454 Series
Page 28: ...Tables xxviii Cisco ONS 15454 Procedure Guide R5 0 December 2004 ...
Page 44: ...Tasks xliv Cisco ONS 15454 Procedure Guide R5 0 December 2004 ...
Page 53: ...liii Cisco ONS 15454 Procedure Guide R5 0 December 2004 About this Guide Document Conventions ...
Page 55: ...lv Cisco ONS 15454 Procedure Guide R5 0 December 2004 About this Guide Document Conventions ...
Page 850: ...Index IN 22 Cisco ONS 15454 Procedure Guide R5 0 December 2004 description 4 11 remove 18 23 ...