Cisco ONS 15327 User Documentation, R3.3
June 2002
Chapter 14 Alarm Troubleshooting
Alarm Procedures
Step 4
Click
Apply
.
14.4.83 MANRESET
•
Not Alarmed (NA) (Condition)
A manual system reset (MANRESET) condition means a user performed a manual system reset by
right-clicking a card and chose
Reset
. Resets performed during a software upgrade also prompt the
alarm. This condition clears automatically, when the card finishes resetting.
14.4.84 MAN-REQ
•
Not Alarmed (NA) (Condition)
The manual switch request on a facility/equipment (MAN-REQ) alarm occurs when a user initiates a
manual switch request on an OC-N card or UPSR path. Clearing the manual switch clears the
MANUAL-REQ alarm.
Procedure: Clear the Manual Switch and the MAN-REQ Condition on an OC-N Card
Step 1
From network view, click the
Circuits
tab.
Step 2
Highlight the circuit.
Step 3
Click
Edit
and click the
UPSR
tab.
Step 4
From the Switch State menu, highlight
Clear
.
Step 5
Click
Apply
and click
Close
.
14.4.85 MEA (AIP)
•
Critical, Service-Affecting
If the mismatch between entity/equipment type and provisioned attributes (MEA) alarm is reported
against the AIP, the fuse in the AIP board may have blown, and the AIP needs replacement.
Procedure: Clear the MEA Alarm on the AIP
Step 1
The fuse in the AIP board may be blown and the board needs to be replaced. Login to
http://www.cisco.com/TAC for information on obtaining a return materials authorization (RMA) for the
AIP or call the Cisco Technical Assistance Center (1-800-553-2447).
Summary of Contents for ONS 15327
Page 22: ...Contents xxii Cisco ONS 15327 User Documentation June 2002 I N D E X ...
Page 30: ...Figures xxviii Cisco ONS 15327 User Documentation June 2002 ...
Page 44: ...Procedures xlii Cisco ONS 15454 Installation and Operations Guide R3 2 June 2002 ...
Page 540: ...Glossary GL 16 Cisco ONS 15327 User Documentation R3 3 June 2002 ...