1-44
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
78-17235-01
Chapter 1 General Troubleshooting
1.7 Restore the Database and Default Settings
d.
Select the appropriate state (IS; OOS,DSBLD; OOS,MT) in the Admin State column for the port
being tested.
e.
Click
Apply
.
f.
Click
Yes
in the confirmation dialog box.
Step 6
Clear the terminal loopback circuit:
a.
Click the
Circuits
tab.
b.
Choose the loopback circuit being tested.
c.
Click
Delete
.
d.
Click
Yes
in the Delete Circuits dialog box. Do not check any check boxes.
The entire circuit path has now passed its comprehensive series of loopback tests. This circuit qualifies
to carry live traffic.
1.7 Restore the Database and Default Settings
This section contains troubleshooting procedures for errors that require restoration of software data or
the default node setup.
1.7.1 Restore the Node Database
Symptom
One or more nodes are not functioning properly or have incorrect data.
Table 1-1
describes the potential cause of the symptom and the solution.
1.8 PC Connectivity Troubleshooting
This section contains information about system minimum requirements, supported platforms, browsers,
and Java Runtime environments (JREs) for Software Release 7.0, and troubleshooting procedures for
Windows PC and network connectivity to the ONS 15310-CL or ONS 15310-MA.
1.8.1 Windows PC System Minimum Requirements
Workstations running CTC Software R7.0 for the ONS products on Windows platforms need to have the
following minimum requirements:
•
Pentium III or higher processor
Table 1-1
Restore the Node Database
Possible Problem
Solution
Incorrect or corrupted
node database.
Complete the applicable procedures in the “Maintain the Node” chapter of
the
Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide
.