1-34
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
78-17235-01
Chapter 1 Error Messages
EID-5033
Unable to load profile.
Error decoding characters.
CTC detected an error while decoding
characters and could not load the profile.
EID-5034
Unable to load profile.
File format error.
CTC detected an error and could not load
the profile.
EID-5035
Unable to load profile.
File read error.
CTC could not read the file and is therefore
unable to load the profile.
EID-5036
The GNE Host Name {0} is invalid.
The specified host name is invalid. CTC
could not resolve the host name to any valid
IP address
EID-5037
Provisionable patchcords cannot be created between
transponder trunk ports and mux/demux ports on the same
node.
You must create provisionable patchcords
between transponder trunk ports and
mux/demux ports that are on different
nodes.
EID-5038
Provisionable patchcords created between transponder trunk
ports and mux/demux ports must use the same wavelength:
{0} is not equal to {1}.
Wavelengths used by provisionable
patchcords for transponser trunk ports and
mux/demux ports must be the same.
EID-5039
Provisionable patchcords created between transponder trunk
ports and mux/demux ports must use the same wavelength:
{0} is not equal to {1}.
Please provision the {2} wavelength on {3}.
Transmitter and receiver port wavelengths
are not equal. Provision the receiver and
transmitter wavelengths on transmitter and
receiver ports respectively.
EID-5040
Provisionable patchcords between OC3/OC12 ports and
mux/demux ports are not supported.
Refer to the error message text.
EID-5041
Provisionable patchcords between non-colored OCn trunk ports
and mux/demux ports are not supported.
Refer to the error message text.
EID-5042
Provisionable patchcords created between OCn trunk ports and
mux/demux ports must use the same wavelength:
{0} is not equal to {1}.
Wavelengths used by provisionable
patchcords for OC-N trunk ports and
mux/demux ports must be the same.
WID-5043
Warning: line card is only provisioned:
wavelength compatibility check is skipped.
Refer to the warning message text.
EID-5044
Virtual link can be used only for OCH trail circuits.
Refer to the error message text.
EID-5045
Virtual link does not have wavelength available.
Set wavelengths for the virtual link and
proceed.
WID-5046
Warning: if you select "Use OCHNC Direction" your circuit
will be limited to nodes prior to release 07.00.
Refer to the warning message text.
EID-5047
Provisionable patchcords between OC3/OC12 ports are not
supported.
Refer to the error message text.
EID-5048
Provisionable patchcords between non-colored OCn trunk ports
are not supported.
Refer to the error message text.
EID-5049
Provisionable patchcords between non-colored OCn trunk ports
and mux/demux ports are not supported.
Refer to the error message text.
EID-5050
Cannot find Element Model:
{0}
The specified Element Model cannot be
located.
Table 1-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
Description