Figure 3-25 Installing a Hub Filter module in an ONS 15252 MCU
Procedure: Install the Bridge Module in the ONS 15252 MCU Passive Optical Shelf
You will install one BM, or one or two TMs, but not both a BM and a TM together. See the
Termination Module in the ONS 15252 MCU Passive Optical Shelf” procedure on page 3-36
. You can
also install a combination of Connection Module Xs (CMXs) and Connection Module Ys (CMYs). See
the
“Install a Connection Module X in Two ONS 15252 MCUs” procedure on page 3-37
and the
a Connection Module Y in Two ONS 15252 MCUs” procedure on page 3-38
illustrates a
BM installation.
Step 1
Position the BM into the passive optical shelf at the end of the A-side and B-side rows of HFMs. Place
one side of the BM at the end of the A-side row of HFMs and the other side of the BM at the end of the
B-side row of HFMs.
Step 2
Carefully slide each side of the BM into the passive optical shelf. Be sure the passive optical shelf
crossbeam and the slot on the bottom of each side of the BM connect properly.
54867
HFM