background image

Cisco Nexus 9358GY-FXP NX-OS Mode Switch Hardware Installation
Guide

First Published:

2019-12-23

Americas Headquarters

Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000

800 553-NETS (6387)

Fax: 408 527-0883

Summary of Contents for Nexus 9358GY-FXP

Page 1: ...S Mode Switch Hardware Installation Guide First Published 2019 12 23 Americas Headquarters Cisco Systems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 ...

Page 2: ...nna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Modifications to this product not authorized by Cisco could void the FCC approval and negate your authority to operate the product The Cisco implementation of TCP hea...

Page 3: ... Requirements 5 Dust and Particulate Requirements 5 Minimizing Electromagnetic and Radio Frequency Interference 6 Shock and Vibration Requirements 7 Grounding Requirements 7 Rack and Cabinet Requirements 7 Installing the Switch Chassis 9 C H A P T E R 3 Safety 9 Installation Guidelines 10 Unpacking and Inspecting the Switch 10 Attaching L Brackets to the Chassis 11 Attaching Magnet to the Chassis ...

Page 4: ...uirements for Cabinets and Racks 21 Requirements Specific to Standard Open Racks 22 Requirements Specific to Perforated Cabinets 22 Cable Management Guidelines 22 System Specifications 23 A P P E N D I X B Environmental Specifications 23 Switch Dimensions 23 Switch and Module Weights and Quantities 23 Transceiver and Cable Specifications 23 Switch Power Input Requirements 24 Regulatory Standards C...

Page 5: ...ents for which the user supplies the values Italic Square brackets enclose an optional element keyword or argument x Square brackets enclosing keywords or arguments separated by a vertical bar indicate an optional choice x y Braces enclosing keywords or arguments separated by a vertical bar indicate a required choice x y Nested set of square brackets or braces indicate optional or required choices...

Page 6: ...of code indicates a comment line Documentation Feedback To provide technical feedback on this document or to report an error or omission please send your comments to We appreciate your feedback Obtaining Documentation and Submitting a Service Request For information on obtaining documentation using the Cisco Bug Search Tool BST submitting a service request and gathering additional information see ...

Page 7: ...ables this switch supports see the Cisco Transceiver Modules Compatibility Information document This switch is supported on second generation NX OS mode switches only Note The baseline memory utilization of this switch is about 80 This is expected behavior Note Due to the limited number of SFP ports on this switch we suggest that you connect the APIC to another leaf switch within your fabric if po...

Page 8: ...8 ports 2 3 USB port 6 Console port RS 232 5 The following figure shows the hardware features seen from the power supply side of the chassis Figure 2 Power Supply Side View of the Cisco Nexus 9358GY FXP Switch Grounding pad 2 Power supply 1 The following figure shows the hardware features seen from the side of the chassis Cisco Nexus 9358GY FXP NX OS Mode Switch Hardware Installation Guide 2 Overv...

Page 9: ...B support is limited to USB 2 0 devices that use less than 2 5 W less than 0 5 A inclusive of surge current Devices such as external hard drives that instantaneously draw more than 0 5 A are not supported Note Cisco Nexus 9358GY FXP NX OS Mode Switch Hardware Installation Guide 3 Overview Overview ...

Page 10: ...Cisco Nexus 9358GY FXP NX OS Mode Switch Hardware Installation Guide 4 Overview Overview ...

Page 11: ...ity Requirements Buildings in which the climate is controlled by air conditioning in the warmer months and by heat during the colder months usually maintain an acceptable level of humidity for the switch equipment However if the switch is located in an unusually humid location use a dehumidifier to maintain the humidity within an acceptable range Altitude Requirements Altitude rating is based on p...

Page 12: ...th a blank filler plate Always use shielded cables with metal connector shells for attaching peripherals to the switch When wires are run for any significant distance in an electromagnetic field interference can occur to the signals on the wires with the following implications Bad wiring can result in radio interference emanating from the plant wiring Strong EMI especially when it is caused by lig...

Page 13: ...round You automatically ground AC power supplies when you connect them to AC power sources For DC power supplies you must connect a grounding wire when wiring the power supply to the DC power source Note Rack and Cabinet Requirements You can install the following types of racks or cabinets for your switch Standard perforated cabinets Solid walled cabinets with a roof fan tray bottom to top cooling...

Page 14: ...st be in place or the rack must be bolted to the floor before installation or servicing Failure to stabilize the rack can cause bodily injury Warning Cisco Nexus 9358GY FXP NX OS Mode Switch Hardware Installation Guide 8 Preparing the Site Rack and Cabinet Requirements ...

Page 15: ... a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device SAVE THESE INSTRUCTIONS Warning Statement 1017 Re...

Page 16: ... Typically this often requires one or both of the following AC power supplies typically require at least a 15 A or 20 A AC circuit 100 to 240 VAC and a frequency of 50 to 60 Hz To prevent loss of input power ensure the total maximum loads on the circuits supplying power to the switch are within the current ratings for the wiring and breakers Caution Statement 1005 Circuit Breaker This product reli...

Page 17: ...Model and serial number of the damaged unit Description of damage Effect of damage on the installation Attaching L Brackets to the Chassis You attach two L brackets to each side of the chassis These brackets hold the chassis in place on a flat surface Before you begin You must have the following tools and equipment Phillips head screwdriver L brackets 4 and screws 4 Step 1 Align the hole in the L ...

Page 18: ...Use the magnet on the bottom of the chassis to attach the chassis to a flat surface Grounding the Chassis The switch chassis is automatically grounded when you properly install the switch in a grounded rack with metal to metal connections between the switch and rack You can also ground the chassis which is required if the rack is not grounded by attaching a customer supplied grounding cable Attach...

Page 19: ...ely 0 75 inch 19 mm of the covering from the end of the grounding wire We recommend 6 AWG wire for the U S installations Step 2 Insert the stripped end of the grounding wire into the open end of the grounding lug Use a crimping tool to crimp the lug to the wire see the following figure Verify that the ground wire is securely attached to the grounding lug by attempting to pull the wire out of the c...

Page 20: ... optional jumper power cord to connect the switch to your outlet receptacle Note The switch is not connected to the network this includes any management or interface connections Step 1 For the AC power supply do the following a Using the recommended AC power cable for your country or region connect one end to the AC power supply b Connect the other end of the power cable to the AC power source Ste...

Page 21: ...are connections to hosts and servers in the network Each of these connection types is explained in one of the sections that follow When running cables in overhead or subfloor cable trays we strongly recommend that you locate power cables and other potential noise sources as far away as practical from network cabling that terminates on Cisco equipment In situations where long parallel cable runs ca...

Page 22: ...k which is connected to a power source and grounded The necessary cabling for the console management and network connections must be available An RJ 45 rollover cable provided in the switch accessory kit Network cabling is routed to the location of the installed switch Step 1 Configure the console device to match the following default port characteristics 9600 baud 8 data bits 1 stop bit No parity...

Page 23: ... to the same AC circuit If you are using the input source n n power mode connect half of the power supplies to one AC circuit And connect the other half of the power supplies to another AC circuit The Input and Output LEDs on each power supply light up green when the power supply units are sending power to the switch and the software asks you to specify a password to use with the switch Step 2 Ent...

Page 24: ...o not to edit the configuration The software asks if you need to save the configuration Step 8 Enter yes to save the configuration What to do next You can now set up the management interface for each supervisor module on the switch Setting Up the Management Interface The RJ 45 and or SFP management ports provide out of band management which enables you to use the command line interface CLI to mana...

Page 25: ...G adapter in the QSFP port and then install the SFP or SFP transceiver The switch automatically sets the port speed to the speed of the installed transceiver Note If the transceivers that you are using can be separated from their optical cables install the transceivers without their cables before inserting the cables into the transceivers This helps to prolong the life of both the transceiver and ...

Page 26: ...Cisco Nexus 9358GY FXP NX OS Mode Switch Hardware Installation Guide 20 Connecting the Switch to the Network Connecting Interface Ports to Other Devices ...

Page 27: ...acks If you are selecting an enclosed cabinet we recommend one of the thermally validated types either standard perforated or solid walled with a fan tray Note We do not recommend that you use racks that have obstructions such as power strips because the obstructions could impair access to field replaceable units FRUs Note General Requirements for Cabinets and Racks The cabinet or rack must also m...

Page 28: ...en Racks If you are mounting the chassis in an open rack no side panels or doors ensure that the rack meets the following requirements The minimum vertical rack space per chassis must be The distance between the chassis air vents and any walls should be 2 5 inches 6 4 cm Requirements Specific to Perforated Cabinets A perforated cabinet has perforations in its front and rear doors and side walls Pe...

Page 29: ...m Cisco Nexus 9358GY FXP Switch and Module Weights and Quantities Weight per Unit Component 10 lb 6 44 kg Cisco Nexus 9358GY FXP Chassis N9K C9358GY FXP Transceiver and Cable Specifications To determine which transceivers adapters and cables are supported by this switch see https www cisco com c en us support interfaces modules transceiver modules products device support tables list html To see th...

Page 30: ...irement Maximum Power Consumption AC or DC Typical Power Consumption AC or DC Switch 1484 26 BTUs per hour 435 W 427 W Cisco Nexus 9358GY FXP Regulatory Standards Compliance Specifications The following table lists the regulatory standards compliance for the switch Table 1 Regulatory Standards Compliance Safety and EMC Description Specification Products should comply with CE Markings according to ...

Page 31: ... 2 EN61000 3 3 KN22 Class A CNS13438 Class A EMC Emissions EN55024 CISPR24 EN300386 KN 61000 4 series EMC Immunity The product is RoH 6 compliant with exceptions for leaded ball grid array BGA balls and lead press fit connectors RoHS Cisco Nexus 9358GY FXP NX OS Mode Switch Hardware Installation Guide 25 System Specifications System Specifications ...

Page 32: ...Cisco Nexus 9358GY FXP NX OS Mode Switch Hardware Installation Guide 26 System Specifications System Specifications ...

Page 33: ... on PoE ports because providing power exceeds the switch power capacity Amber PoE is disabled Off The operator has activated this LED to identify this switch in the chassis Flashing blue BCN This switch is not being identified Off The switch is operational Green STS The switch is booting up Flashing amber Temperature exceeds the minor alarm threshold Amber Temperature exceeds the minor alarm thres...

Page 34: ... admin state is Enabled SFP is present and the interface is connected that is cabled and the link is up Green port Port admin state is Disabled or the SFP is absent or both Amber Port admin state is Enabled and SFP is present but interface is not connected Off Cisco Nexus 9358GY FXP NX OS Mode Switch Hardware Installation Guide 28 LEDs LEDs ...

Reviews: