Uplink Module LEDs
The Status (STS) LED is located on the left side of the uplink module. There is an ACT LED located below
each two uplink ports. Next to each ACT LED are two triangular port LEDs that point to the top or bottom
to identify their port as being the top or bottom port.
Status
Color
LED
This module is operational.
Green
STS
Temperature is not operational.
Red
The module is not receiving power.
Off
The two ports above this LED are enabled.
On (white)
ACT
The two ports above this LED are not enabled.
Off
The port is connected with a transceiver or other connector.
Green
(port)
The port is not connected.
Off
Fan Module LEDs
The fan module LED is located below the air holes on the front of the module.
Status
Color
LED
The fan module is operational.
Green
STS
The fan module is not operational (fan is probably not functional).
Red
Fan module is not receiving power.
Off
Power Supply LEDs
The power supply LEDs are located on the left front portion of the power supply. Combinations of states
indicated by the Okay (
) and Fault (
) LEDs indicate the status for the module as shown in the following
table.
Cisco Nexus 9396PX NX-OS Mode Switch Hardware Installation Guide
58
LEDs
Uplink Module LEDs