Description
Usage
Module Terms
If you are logged into the active supervisor, the following
applies:
•
sup-local refers to the active supervisor module.
•
sup-remote refers to the standby supervisor module.
If you are logged into the standby supervisor, the following
applies:
•
sup-local refers to the standby supervisor module (the
one that you are logged into).
•
There is no sup-remote available from the standby
supervisor module (you cannot access a file system on
the active supervisor).
Relative
sup-local and sup-remote
Shutting Down a Supervisor Module
To shut down a supervisor module, use the
out-of-service module
command to specify the chassis slot with
that module.
Procedure
Step 1
Start the configuration mode by entering the
configure terminal
command.
Example:
switch#
configure terminal
switch(config)#
Step 2
Take the supervisor module out of service by entering the
out-of-service module slot_number
command.
Example:
switch(config)#
out-of-service module 9
switch(config)#
Overview of I/O Module Support
The following table lists the I/O modules supported by the switch.
Cisco Nexus 7718 Switch Site Preparation and Hardware Installation Guide
76
OL-30453-01
Managing the Switch
Shutting Down a Supervisor Module