Fabric Module LEDs
Status
Color
LED
All diagnostics pass. The module is operational (normal initialization
sequence).
Green
Status
Indicates one of the following:
•
The diagnostic test has failed. The module is not operational because
a fault has occurred during the initialization sequence.
•
The inlet air temperature of the system has exceeded the safe
operating temperature limits of the card (a major environmental
warning). The card has been shut down to prevent permanent
damage.
Red
Indicates one of the following:
•
The fabric module has just been inserted and is booting up.
•
An overtemperature condition has occurred and the module has
powered down.
•
The power was turned off with a CLI command.
•
The module is resetting and both ejector levers are out.
Flashing red
The
operator
has
activated
this
LED to
identify
this
module
in the
chassis.
Flashing blue
ID
This module is not being identified.
Off
Cisco Nexus 7718 Switch Site Preparation and Hardware Installation Guide
OL-30453-01
195
LEDs
Fabric Module LEDs