8
L2L3Dev2Sn2(s13 125
115
66
Ok
8
L3Lkup2Sn1(s14) 125
105
55
Ok
8
L3Lkup2Sn2(s15) 125
105
56
Ok
9
Inlet
(s1)
60
42
17
Ok
9
Crossbar(s2)
125
115
64
Ok
9
L2L3Dev1(s3)
125
110
42
Ok
9
Arbiter (s4)
125
105
57
Ok
9
CPU1CORE1(s5)
85
75
29
Ok
9
CPU1CORE2(s6)
85
75
27
Ok
9
CPU1CORE3(s7)
85
75
30
Ok
9
CPU1CORE4(s8)
85
75
29
Ok
9
CPU2CORE1(s9)
85
75
24
Ok
9
CPU2CORE2(s10)
85
75
21
Ok
9
CPU2CORE3(s11)
85
75
23
Ok
9
CPU2CORE4(s12)
85
75
21
Ok
9
DDR3DIMM1(s13)
95
85
28
Ok
9
DDR3DIMM2(s14)
95
85
27
Ok
9
DDR3DIMM4(s16)
95
85
21
Ok
9
DDR3DIMM5(s17)
95
85
22
Ok
10
L2L3Dev1(s3)
125
110
49
Ok
10
Arbiter (s4)
125
105
61
Ok
10
CPU1CORE1(s5)
85
75
41
Ok
10
CPU1CORE2(s6)
85
75
37
Ok
10
CPU1CORE3(s7)
85
75
39
Ok
10
CPU1CORE4(s8)
85
75
38
Ok
10
CPU2CORE1(s9)
85
75
26
Ok
10
CPU2CORE2(s10)
85
75
23
Ok
10
CPU2CORE3(s11)
85
75
24
Ok
10
CPU2CORE4(s12)
85
75
22
Ok
10
DDR3DIMM1(s13)
95
85
30
Ok
10
DDR3DIMM2(s14)
95
85
28
Ok
10
DDR3DIMM4(s16)
95
85
25
Ok
10
DDR3DIMM5(s17)
95
85
26
Ok
switch#
Displaying Temperatures for Modules
Each supervisor, I/O, and fabric module has temperature sensors with two thresholds:
• Minor temperature threshold—When a minor threshold is exceeded, a minor alarm occurs and the
following actions occur for all four sensors:
• Displays system messages
• Sends Call Home alerts (if configured)
• Sends SNMP notifications (if configured)
• Major temperature threshold—When a major threshold is exceeded, a major alarm occurs and the following
actions occur:
• For sensors 1, 3, and 4 (outlet and onboard sensors), the following actions occur:
• Displays system messages.
• Sends Call Home alerts (if configured). For more information, refer
Cisco Nexus 7706 Hardware Installation Guide
OL-31330-01
60
Managing the Switch
Displaying Temperatures for Modules