The module should be fully inserted in the slot and the front of the module should be even with the fronts of all of
the other installed modules. The captive screw by the ejector button on the module should be aligned to a screw hole
on the chassis.
Figure 16: Securing a Supervisor Module to its Slot
Tighten the captive screw to 8 in-lb (0.9 N·m) of
torque.
2
Rotate the handle all the way to the front of the
module.
1
g) Screw in the captive screw to secure the module to the chassis (see Callout 2 in the previous figure). Tighten the
screw to 8 in-lb (0.9 N·m) of torque.
h) Verify that the supervisor module LEDs turn on and appear as follows:
•
STATUS LED is green.
•
SYSTEM LED is green.
•
ACTIVE LED is amber or green.
For more information about the LED states for this module, see
Supervisor Module LEDs, on page 123
.
i) Attach the management cable to the MGMT ETH port.
The MGMT ETH LED should be green. If not, see
Supervisor Module LEDs, on page 123
for information about the
LED states.
Installing or Replacing an I/O Module
Before You Begin
•
You must follow ESD protocols, including the following:
◦
You must wear a grounded ESD wristband (or other personal grounding device) whenever you
handle the electronic modules outside the grounded chassis.
◦
You must carry electronic modules by only their covered edges or handles. Do not touch their
electronic components.
Cisco Nexus 7702 Hardware Installation Guide
61
Installing or Replacing Modules, Fan Trays, and Power Supplies
Installing or Replacing an I/O Module