A combination of 3-kW DC and 3.5-kW HVAC/HVDC power supplies can be used.
Note
Overview of Fan Trays
The Cisco Nexus 7702 switch has one fan tray with three variable speed fans. The fan tray can be removed
and replaced while the switch is operating without presenting an electrical hazard or damage to the switch.
The switch can operate without the fan tray for up to two minutes. If a fan tray is not installed within that
time, the switch will automatically shutdown.
When one of the three fans in the fan tray fails, the remaining two fans run at a higher speed to compensate
for the failed fan and keep the switch operating.
Note
If one or more fans fail within a fan tray, the Fan Status LED turns red. A fan failure could lead to
temperature alarms if not corrected immediately.
Caution
The fan status is continuously monitored by the software. In case of a fan failure, the following actions occur:
•
System messages are displayed.
•
Call Home alerts are sent (if configured). For more information, refer
Associating an Alert Group with
.
•
SNMP notifications are sent (if configured). For more information, refer
.
Displaying the Status for the Fan Trays
To display the status for the , use the
show environment fan
command as shown in the following example.
Enter the
show environment fan
command.
Cisco Nexus 7702 Hardware Installation Guide
56
Managing the Switch
Overview of Fan Trays