S e n d f e e d b a c k t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
1-6
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01
Chapter 1 Configuring SAN Port Channels
Configuring SAN Port Channels
Figure 1-6
Misconfigured Configurations
This section shows how to configure and modify SAN port channels and includes the following topics:
•
SAN Port Channel Configuration Guidelines, page 1-6
•
Creating a SAN Port Channel, page 1-7
•
About SAN Port Channel Modes, page 1-7
•
About SAN Port Channel Deletion, page 1-8
•
Deleting SAN Port Channels, page 1-9
SAN Port Channel Configuration Guidelines
Before configuring a SAN port channel, consider the following guidelines:
•
Configure the SAN port channel using Fibre Channel ports from both expansion modules to provide
increased availability (if one of the expansion modules failed).
•
Ensure that one SAN port channel is not connected to different sets of switches. SAN port channels
require point-to-point connections between the same set of switches.
If you misconfigure SAN port channels, you may receive a misconfiguration message. If you receive this
message, the port channel’s physical links are disabled because an error has been detected.