S e n d f e e d b a c k t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
1-18
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01
Chapter 1 Configuring Domain Parameters
FC IDs
Step 6
Enable the HBA interface in the Cisco Nexus 5000 Series switch.
switch#
configuration terminal
switch(config)#
interface vfc20/1
switch(config-if)#
no
shutdown
switch(config-if)#
end
switch#
Step 7
Verify the pWWN ID of the HBA by using the
show flogi database
command.
switch#
show flogi database
------------------------------------------------------------------------------------------
INTERFACE
VSAN
FCID
PORT NAME
NODE NAME
------------------------------------------------------------------------------------------
vfc20/1
3
0x6fee00
50:05:08:b2:00:71:c8:c2
50:05:08:b2:00:71:c8:c0
fc2/3
3
0x6f7704
50:06:0e:80:03:29:61:0f
50:06:0e:80:03:29:61:0f
Note
Both FC IDs now have different area assignments.
About Persistent FC ID Selective Purging
Persistent FC IDs can be purged selectively. Static entries and FC IDs currently in use cannot be deleted.
identifies the FC ID entries that are deleted or retained when persistent FC IDs are purged.
Purging Persistent FC IDs
To purge persistent FC IDs, perform this task:
Table 1-1
Purged FC IDs
Persistent FC ID state
Persistent Usage State
Action
Static
In use
Not deleted
Static
Not in use
Not deleted
Dynamic
In use
Not deleted
Dynamic
Not in use
Deleted
Command
Purpose
Step 1
switch#
purge fcdomain fcid vsan
vsan-id
Purges all dynamic and unused FC IDs in the specified
VSAN.
switch#
purge fcdomain fcid vsan
vsan-id
-
vsan-id
Purges dynamic and unused FC IDs in the specified VSAN
range.