Clear the DUP-NODENAME Alarm
SUMMARY STEPS
1.
In node view (single-shelf mode) or multishelf view (multishelf mode), click the
Provisioning
>
General
>
General
tabs.
2.
In the Node Name field, enter a unique name for the node.
3.
Click
Apply.
DETAILED STEPS
Step 1
In node view (single-shelf mode) or multishelf view (multishelf mode), click the
Provisioning
>
General
>
General
tabs.
Step 2
In the Node Name field, enter a unique name for the node.
Step 3
Click
Apply.
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
DUP-SHELF-ID
Default Severity: Major (MJ), Service-Affecting (SA)
Logical Object: SHELF
The Duplicated Shelf Identifier alarm applies to a shelf that has multishelf management enabled when the
control card detects that you have programmed an ID already in use by another shelf.
Clear the DUP-SHELF-ID Alarm
SUMMARY STEPS
1.
Unprovision the shelf ID of the duplicate shelf by completing the following steps:
DETAILED STEPS
Unprovision the shelf ID of the duplicate shelf by completing the following steps:
a) In shelf view (multishelf mode) or multishelf view (multishelf mode), click the node controller
Provisioning
>
General
>
Multishelf Config
tabs.
b) Enter a new value in the
Shelf ID
field.
c) Click
Apply
If the alarm does not get cleared, you need to report a Service-Affecting (SA) problem. Log into the Technical Support
Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or log into
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
169
Alarm Troubleshooting