show controllers
To display status and configuration information about the interfaces on a specific node, use the
show controllers
command in XR EXEC mode.
show controllers controllertype
R/S/I/P
[
pm
{
current
|
history
}
{
30 sec
|
15-min
|
24-hour
} {
optics
|
ether
|
pcs
|
prbs
}
linenumber
{
otn
|
fec
}
]
To view the the bits-per-symbol or baud rate of the optics controller for a specific range use the following
command:
show controllers optics
R/S/I/P
{
bps-range
bps-range
|
baud-rate-range
baud-range
}
|
include
data-rate
| include
fec-type
Syntax Description
Type of the controller. The possible values are HundredGigECtrlr,
CoherentDSP, ODU4, and Optics.
controllertype
Rack/Slot/Instance/Port of the controller.
R/S/I/P
Displays performance monitoring parameters for the controller.
pm
Displays the current performance monitoring data in 30 second, 15 minute,
and 24 hour intervals.
current
Displays the historical performance monitoring data in 30 second, 15 minute,
and 24 hour intervals.
history
optics to display the PM data for Optics controller, ether, pcs, and prbs to
display the PM data for Ethernet controller.
optics
|
ether
|
pcs
|
prbs
Line number to display performance monitoring data. The range is 1 to 4.
linenumber
Displays OTN PM data or FEC PM data for CoherentDSP controller.
otn
|
fec
Displays the BPS for the specified range.
bps-range bps-range
Displays the baud rates for the specified range.
baud-rate-range baud-range
Filters the show command output so that it displays only lines that contain
a particular regular expression.
| include
Data rate for which the BPS or baud rate is displayed.
data-rates
FEC type for which the BPS or baud rate is displayed.
fec-type
Usage Guidelines
The following table describes the PRBS parameters.
Description
Parameter
Cumulative count of PRBS bit errors in the sampling window (15 min or 24
hour). Bit errors are accumulated only if PRBS signal is locked.
EBC
Command Reference for Cisco NCS 1004
70
Commands
show controllers