Cisco N9K-C9332PQ Hardware Installation Manual Download Page 1

Cisco Nexus 9332PQ ACI-Mode Switch Hardware Installation Guide

First Published:

2015-08-04

Last Modified:

2019-03-28

Americas Headquarters

Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000

800 553-NETS (6387)

Fax: 408 527-0883

Summary of Contents for N9K-C9332PQ

Page 1: ...ardware Installation Guide First Published 2015 08 04 Last Modified 2019 03 28 Americas Headquarters Cisco Systems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 ...

Page 2: ...o try to correct the interference by using one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Modifications to this product not authorized b...

Page 3: ...P T E R 2 Temperature Requirements 5 Humidity Requirements 5 Altitude Requirements 5 Dust and Particulate Requirements 6 Minimizing Electromagnetic and Radio Frequency Interference 6 Shock and Vibration Requirements 7 Grounding Requirements 7 Planning for Power Requirements 7 Airflow Requirements 9 Rack and Cabinet Requirements 9 Clearance Requirements 10 Installing the Switch Chassis 13 C H A P T...

Page 4: ...nstalling a Gigabit Ethernet module GEM 34 Virtual Port Channel Migration Migration of Nodes from a First Generation Switch to a Second Generation Switch 34 Setting Up an Optional Console Interface 35 Setting Up an Optional Management Connection 36 Optic Transceiver Removal Using the Optics Extraction Tool 36 Maintaining Transceivers and Optical Cables 37 Replacing Components 39 C H A P T E R 5 Re...

Page 5: ...930 W DC Power Supply Port Side Exhaust Specifications 50 Power Cable Specifications 51 Power Cable Specifications for AC Power Supplies 51 HVAC HVDC Power Cables Supported by ACI Mode and NX OS Mode Switches 52 DC Power Cable Specifications 53 Regulatory Standards Compliance Specifications 53 LEDs 55 A P P E N D I X C Switch Chassis LEDs 55 Lane Link LEDs 56 Fan Module LEDs 56 Power Supply LEDs 5...

Page 6: ...Chassis and Module Information 63 Cisco Nexus 9332PQ ACI Mode Switch Hardware Installation Guide vi Contents ...

Page 7: ...text indicates arguments for which the user supplies the values Italic Square brackets enclose an optional element keyword or argument x Square brackets enclosing keywords or arguments separated by a vertical bar indicate an optional choice x y Braces enclosing keywords or arguments separated by a vertical bar indicate a required choice x y Nested set of square brackets or braces indicate optional...

Page 8: ...vailable on Cisco com at the following URL https www cisco com c en us support cloud systems management application policy infrastructure controller apic tsd products support series home html Web Based Documentation Cisco APIC Management Information Mode Reference Cisco APIC Online Help Reference Cisco APIC Python SDK Reference Cisco ACI Compatibility Tool Cisco ACI MIB Support List Downloadable D...

Page 9: ...dware Installation Guide Cisco Nexus 93120TX ACI Mode Switch Hardware Installation Guide Cisco Nexus 93128TX ACI Mode Switch Hardware Installation Guide Cisco Nexus 93180LC EX ACI Mode Switch Hardware Installation Guide Cisco Nexus 93180YC EX ACI Mode Switch Hardware Installation Guide Cisco Nexus 93180YC FX ACI Mode Switch Hardware Installation Guide Cisco Nexus 9332PQ ACI Mode Switch Hardware In...

Page 10: ...ps www cisco com c en us support switches application virtual switch tsd products support series home html Documentation Feedback To provide technical feedback on this document or to report an error or omission please send your comments to apic docfeedback cisco com We appreciate your feedback Obtaining Documentation and Submitting a Service Request For information on obtaining documentation using...

Page 11: ...this switch includes the following user replaceable components Fan modules four with the following airflow choices Port side intake fan module with burgundy coloring NXA FAN 30CFM B Port side exhaust fan module with blue coloring NXA FAN 30CFM F Power supplies two one for operations and one for redundancy 1 1 with the following choices 650 W AC power supply with port side intake airflow burgundy c...

Page 12: ... and Environment ENV LEDs 3 40 Gigabit QSFP APIC facing interface ports 26 Ports 1 to 12 and 15 to 26 also support 40 Gigabit to 4x10 Gigabit breakout cables with the Dynamic Breakout feature 4 To determine which transceivers adapters and cables are supported by this switch see the Cisco Transceiver Modules Compatibility Information document The following figure shows the switch features on the po...

Page 13: ...installed and operating If you have only one power supply installed you can install the replacement power supply in the open slot before removing the original power supply All of the fan and power supply modules must have the same direction of airflow Otherwise the switch can overheat and shut down If you are installing a dual direction power supply that module will automatically use the same airf...

Page 14: ...Cisco Nexus 9332PQ ACI Mode Switch Hardware Installation Guide 4 Overview Overview ...

Page 15: ... 40 to 70 degrees Celsius Humidity Requirements High humidity can cause moisture to enter the switch Moisture can cause corrosion of internal components and degradation of properties such as electrical resistance thermal conductivity physical strength and size The switch is rated to withstand from 5 to 95 percent noncondensing relative humidity Buildings in which the climate is controlled by air c...

Page 16: ...o other devices through the power cable and power source or through the air as transmitted radio waves The Federal Communications Commission FCC publishes specific regulations to limit the amount of EMI and RFI that are emitted by computing equipment Each switch meets these FCC regulations To reduce the possibility of EMI and RFI follow these guidelines Cover all open expansion slots with a blank ...

Page 17: ...properly install the chassis in a grounded rack the switch is grounded because it has a metal to metal connection to the rack Alternatively you can ground the chassis by using a customer supplied grounding cable that meets your local and national installation requirements For U S installations we recommend 6 AWG wire Connect your grounding cable to the chassis with a grounding lug provided in the ...

Page 18: ...ease refer to the following statement Note Statement 1005 Circuit Breaker This product relies on the building s installation for short circuit overcurrent protection Ensure that the protective devices are rated not greater than 20A North America 16A Europe and 13A UK Warning For DC input application please refer to the following statement Note Statement 1005 Circuit Breaker This product relies on ...

Page 19: ...ies indicates port side exhaust airflow Green coloring on DC power supplies indicates port side intake airflow To prevent the switch from overheating and shutting down you must position the air intake for the switch in a cold aisle The fan and power supply modules must have the same direction of airflow even if their coloring is different If you must change the airflow direction for the switch you...

Page 20: ... within reach of the power cords that are used with the switch Statement 1048 Rack Stabilization The rack stabilizing mechanism must be in place or the rack must be bolted to the floor before installation or servicing Failure to stabilize the rack can cause bodily injury Warning Clearance Requirements Provide the chassis with adequate clearance between the chassis and any other rack device or stru...

Page 21: ...front clearance area equal to the width of the chassis with two rack mount brackets that are attached to it 4 Both the front and rear of the chassis must be open to both aisles for airflow Note Cisco Nexus 9332PQ ACI Mode Switch Hardware Installation Guide 11 Preparing the Site Clearance Requirements ...

Page 22: ...Cisco Nexus 9332PQ ACI Mode Switch Hardware Installation Guide 12 Preparing the Site Clearance Requirements ...

Page 23: ...r service the switch see the Regulatory Compliance and Safety Information for the Cisco Nexus 3000 and 9000 Series for important Safety Information Statement 1071 Warning Definition IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be fa...

Page 24: ...N3K C3064 ACC KIT which you can order from Cisco You can install the switch in the following types of racks Open EIA rack Perforated EIA cabinet The rack or cabinet that you use must meet the requirements listed the in General Requirements for Cabinets and Racks on page 45 section You are responsible for verifying that your rack and rack mount hardware comply with the guidelines that are described...

Page 25: ...irements for the switch If available you can use an uninterruptible power supply UPS to protect against power failures Avoid UPS types that use ferroresonant technology These UPS types can become unstable with the switch which can have substantial current draw fluctuations because of fluctuating data traffic patterns Caution Ensure that circuits are sized according to local and national codes Typi...

Page 26: ...tative immediately Keep the shipping container in case the chassis requires shipping at a later time Tip Before you begin Before you unpack the switch and before you handle any switch components be sure that you are wearing a grounded electrostatic discharge ESD strap To ground the strap attach it directly to an earth ground or to a grounded rack or grounded chassis there must be a metal to metal ...

Page 27: ...to the front of the rack Typically the front of the rack is the side easiest to access for maintenance You must supply the eight 10 32 or 12 24 screws required to mount the slider rails and switch to the rack Note Before you begin You have inspected the switch shipment to ensure that you have everything ordered Make sure that the switch rack mount kit includes the following parts Front rack mount ...

Page 28: ...terface cables 3 inches 7 6 mm minimum and module handles 1 inch 2 5 mm minimum Note c Secure the front mount bracket and the back mount bracket to the chassis using four M4 screws and tighten each screw to 12 in lb 1 36 N m of torque d Repeat Step 1 for the other front rack mount bracket and the other back mount bracket on the other side of the switch and be sure to position that bracket the same...

Page 29: ...m of torque and tighten 10 32 screws to 20 in lb 2 26 N m of torque c Repeat Step 3 to attach the other slider rail to the other side of the rack To make sure that the slider rails are at the same level you should use a level tool tape measure or carefully count the screw holes in the vertical mounting rails Step 4 Insert the switch into the rack and attach it as follows a Holding the switch with ...

Page 30: ... m or tighten the 12 24 screws to 30 in lb 3 39 N m Step 5 If you attached a grounding wire to the chassis grounding pad connect the other end of the wire to the facility ground InstallingtheSwitchUsingtheN3K C3064 ACC KITRack Mount Kit To install the switch you must attach front and rear mounting brackets to the switch install slider rails on the rear of the rack slide the switch onto the slider ...

Page 31: ...aisle If the power supply modules have white coloring look at the fan modules to determine the airflow direction for the switch Note b Position a front mount bracket so that four of its screw holes are aligned to the screw holes on the side of the chassis You can align any four of the holes in the front rack mount bracket to four of the six screw holes on the side of the chassis see the two ways t...

Page 32: ...ide of the switch and be sure to position that bracket the same distance from the front of the switch Step 2 Install the two rear rack mount brackets on the chassis as follows a Align the two screw holes on a rear rack mount bracket to the middle two screw holes in the remaining six screw holes on a side of the chassis If you are aligning the guide to holes that are near the port connections end o...

Page 33: ... attach the rails to the rack see the following figure Tighten 12 24 screws to 30 in lb 3 39 N m of torque and tighten 10 32 screws to 20 in lb 2 26 N m of torque Two customer supplied 12 24 or 10 32 screws used to attach each slider rail to the rack 2 Slider rail with screw holes aligned to screw holes in rack 1 c Repeat Step 3 to attach the other slider rail to the other side of the rack To make...

Page 34: ... the way into the rack until the front rack mount brackets come in contact with two rack or cabinet posts If you attached a grounding cable to the chassis you will need to bend one of the rack mount rails slightly to allow the grounding lug to go behind the rail Note c Holding the chassis level insert two screws 12 24 or 10 32 depending on the rack type in each of the two front rack mount brackets...

Page 35: ...metal connections between the switch and rack You can also ground the chassis which is required if the rack is not grounded by attaching a customer supplied grounding cable Attach the cable to the chassis grounding pad and the facility ground Statement 1024 Ground Conductor This equipment must be grounded To reduce the risk of electric shock never defeat the ground conductor or operate the equipme...

Page 36: ...rimping tool to crimp the lug to the wire see the following figure Verify that the ground wire is securely attached to the grounding lug by attempting to pull the wire out of the crimped lug 2 M4 screws are used to secure the grounding lug to the chassis 3 Chassis grounding pad 1 Grounding cable with 0 75 in 19 mm of insulation that is stripped from one end which is inserted into the grounding lug...

Page 37: ... recommended AC power cable for your country or region connect one end to the AC power supply b Connect the other end of the power cable to the AC power source Step 2 For each HVAC HVDC power supply connect it to a power source as follows a Using the recommended high voltage power cable for your country or region connect the Anderson Power Saf D Grid connector on the power cable to the power recep...

Page 38: ... avoid an electrical shock hazard e Turn on the power at the circuit breaker for the DC power source Step 4 Verify that the power supply LED is on and green Step 5 Listen for the fans they should begin operating when the power supply is powered Step 6 After the switch boots verify that the following LEDs are lit On the fan modules the Status STA or STS LED is green If a fan module Status LED is no...

Page 39: ...Topology The ACI fabric topology includes the following major components Application Centric Infrastructure Controller APIC appliance cluster of APICs Leaf switches for switch compatibility please see the data sheets here https www cisco com c en us products switches nexus 9000 series switches datasheet listing html Spine switches for switch compatibility please see the data sheets here https www ...

Page 40: ...u shield any potential noise sources by housing them in a grounded metallic conduit Note The optical transceivers that are not already assembled to their cables come separate from their cables To prevent these transceivers and their cables from being damaged we recommend that you keep the transceivers disconnected from their cables when installing them in ports and then insert the optical cable in...

Page 41: ...Controller APIC in your ACI fabric The type of virtual interface card VIC installed on the APIC determines the types of interface cables that you can use to connect the leaf switches to the APICs The VIC 1225T module supports copper connectors copper cables and switches with copper downlink ports such as Cisco Nexus 93108TC EX 93108TC FX 93120TX 93128TX 9372TX 9372TX E and 9396TX switches The VIC ...

Page 42: ...ion see http www cisco com c en us support interfaces modules transceiver modules products installation guides list html Step 2 Connect the other end of the interface cable to a downlink port on a leaf switch For a Cisco 10GBASE LR or SR transceiver and cable insert the transceiver into a downlink optical port on a leaf switch before connecting the cable to the transceiver For Cisco SFP Active Opt...

Page 43: ...6PQ 32 port 100 Gigabit such as N9K X9732C EX supported by Cisco Nexus 9504 and 9508 modular switches 36 port 100 Gigabit such as N9K X9736C FX You cannot include NX OS line cards in the same chassis when running in ACI mode Note Multiple uplinks from a leaf switch to a spine switch is supported A symmetrical topology is recommended so that all devices have equal access to resources Note Step 1 Fo...

Page 44: ...secondary are first generation switches in vPC pair sending traffic as described above To determine which transceivers adapters and cables that this switch supports see http www cisco com c en us support interfaces modules transceiver modules products device support tables list html To see the transceiver specifications and installation information see http www cisco com c en us support interfaces...

Page 45: ...nd generation switch will come up in about 10 to 22 seconds when STP is disabled for the deployed VLANs on the remote devices and there will be traffic drops in the range of 10 to 40 seconds depending upon the flows in the fabric When STP is enabled on the VLANs on the remote devices the traffic loss will be in the range of 40 to 75 seconds depending upon the flows in the fabric Step 7 Disconnect ...

Page 46: ...witch and establish an IP address before you create the management connection Step 1 Connect the interface cable to a management port on the switch Step 2 Connect the other end of the cable to an external hub switch or router Optic Transceiver Removal Using the Optics Extraction Tool You use both ends of the optics extraction tool in this procedure You use the wide end for releasing the bale latch...

Page 47: ... in an antistatic bag or other protective environment Maintaining Transceivers and Optical Cables Transceivers and fiber optic cables must be kept clean and dust free to maintain high signal accuracy and prevent damage to the connectors Contamination increases attenuation loss of light and should be below 0 35 dB Cisco Nexus 9332PQ ACI Mode Switch Hardware Installation Guide 37 Connecting the Swit...

Page 48: ...ectors Touching the ends can leave fingerprints and cause other contamination Clean the connectors regularly the required frequency of cleaning depends upon the environment In addition clean connectors if they are exposed to dust or accidentally touched Both wet and dry cleaning techniques can be effective refer to the fiber optic connection cleaning procedures for your site Inspect routinely for ...

Page 49: ...a cold aisle and exhausts to a hot aisle Otherwise the switch can overheat and shutdown If you are changing the airflow direction of all the modules in the chassis you must shutdown the switch before replacing all the fan and power supply modules with modules using the other airflow direction During operations all of the modules must have the same direction of airflow Caution Removing a Fan Module...

Page 50: ...n and becomes green Replacing a Power Supply Module The switch requires two power supplies for redundancy With one power supply providing the necessary power for operations you can replace the other power supply during operations so long as the new power supply has the same airflow direction as the other modules in the chassis You can replace a power supply with another supported power supply that...

Page 51: ... the connectors Caution Step 2 Install the replacement power supply as follows a Holding the replacement power supply with one hand underneath the module and the other hand holding the handle turn the power supply so that its release latch is on the right side and align the back end of the power supply the end with the electrical connections to the open power supply slot before carefully sliding t...

Page 52: ...onnect the input power to the DC PSU s terminal and the input power to the DC PSU s terminal the PSU will not be damaged and will operate fine after the input power feeds are correctly wired Step 1 Remove a DC power supply as follows a Turn off the circuit breaker for the power feed to the power supply that you are replacing Be sure that the LEDs turn off on the power supply that you are removing ...

Page 53: ...ing the release latch If the power supply does not move out of place it is secured in the slot If the power supply moves carefully press it all the way into the slot until it clicks in place c Attach the power connector block end of the power cable to the electrical outlet on the front of the power supply d Turn on the circuit breaker for the power source e Verify that the power supply is operatio...

Page 54: ...Cisco Nexus 9332PQ ACI Mode Switch Hardware Installation Guide 44 Replacing Components Replacing a DC Power Supply ...

Page 55: ...n racks If you are selecting an enclosed cabinet we recommend one of the thermally validated types either standard perforated or solid walled with a fan tray Note We do not recommend that you use racks that have obstructions such as power strips because the obstructions could impair access to field replaceable units FRUs Note General Requirements for Cabinets and Racks The cabinet or rack must als...

Page 56: ... mounting the chassis in an open rack no side panels or doors ensure that the rack meets the following requirements The minimum vertical rack space per chassis must be one rack unit RU equal to 1 75 inches 4 4 cm The distance between the chassis air vents and any walls should be 2 5 inches 6 4 cm Requirements Specific to Perforated Cabinets A perforated cabinet has perforations in its front and re...

Page 57: ... page 51 Regulatory Standards Compliance Specifications on page 53 Environmental Specifications Specification Environment 32 to 104 F 0 to 40 C Ambient operating temperature Temperature 40 to 158 F 40 to 70 C Ambient nonoperating 5 to 85 Nonoperating Relative humidity 0 to 13 123 feet 0 to 4 000 meters Operating Altitude Switch Dimensions Height Depth Width Switch 1 72 inches 4 4 cm 1 RU 22 5 inch...

Page 58: ...tables list html To see the transceiver specifications and installation information see https www cisco com c en us support interfaces modules transceiver modules products device support tables list html Switch Power Input Requirements The following table lists the typical amount of power that the switch consumes It also lists the maximum amount of power that you must provision for the switch and ...

Page 59: ...dby voltage Climate Savers Platinum Efficiency 80Plus Platinum certified Efficiency rating RSP1 Form factor 650 W AC Power Supply Specifications These specifications apply to the following power supplies N9K PAC 650W N9K PAC 650W B Specification Characteristic Nominal range 100 and 240 VAC Range 90 132 VAC 180 264 VAC AC input voltage Nominal range 50 to 60 Hz Range 47 63 Hz AC input frequency 7 6...

Page 60: ...e 23 A at 48 VDC Maximum DC input current 1104 W Maximum input W 930 W Maximum output power per power supply 35 A sub cycle duration Maximum inrush current 8 ms at 930 W Maximum hold up time 12 VDC Power supply output voltage 12 VDC Power supply standby voltage Greater than 92 at 50 load Efficiency rating RSP1 Form factor 930 W DC Power Supply Port Side Exhaust Specifications These specifications ...

Page 61: ...B C13 C14 2M Cabinet jumper power cord 250 VAC 10 A C14 C13 connectors 2 3 feet 0 7 m CAB C13 CBN 250 V 10 A 8 2 feet 2 5 m CAB 250V 10A AR Argentina 250 VAC 10 A 3112 plug 8 2 feet 2 5 m CAB 9K10A AU Australia 250 V 10 A 6 9 feet 2 1 m CAB 250V 10A BR Brazil 250 VAC 10 A CEE 7 7 plug 8 2 feet 2 5 m CAB 9K10A EU European Union 10 A 8 2 feet 2 5 m CAB IND 10A India Power Cord Jumper C13 C14 Connect...

Page 62: ... 9K10A SW Switzerland 250 VAC 10 A BS1363 plug 13 A fuse 8 2 2 5 m CAB 9K10A UK United Kingdom No power cord included with switch NO POWER CORD All except Argentina Brazil and Japan HVAC HVDCPowerCablesSupportedbyACI ModeandNX OSModeSwitches Photo Cord Set Description Part Number HVAC 2 foot 0 6 m cable with Saf D Grid and SD connectors 277V AC CAB HVAC SD 0 6M HVAC 2 foot 0 6 m cable with Saf D G...

Page 63: ... 930WDC port side intake airflow 8 AWG cable with 3 pin keyed power supply connector and three wires power source connection CAB 48DC 40A 8AWG UCS PSU 6332 DC port side exhaust airflow No power cord included with switch NO POWER CORD All except Argentina Brazil and Japan Regulatory Standards Compliance Specifications The following table lists the regulatory standards compliance for the switch Tabl...

Page 64: ...2 Class A EN55022 Class A ICES003 Class A VCCI Class A EN61000 3 2 EN61000 3 3 KN22 Class A CNS13438 Class A EMC Emissions EN55024 CISPR24 EN300386 KN 61000 4 series EMC Immunity The product is RoH 6 compliant with exceptions for leaded ball grid array BGA balls and lead press fit connectors RoHS Cisco Nexus 9332PQ ACI Mode Switch Hardware Installation Guide 54 System Specifications System Specifi...

Page 65: ...e operator has activated this LED to identify this switch in the chassis Flashing blue BCN This switch is not being identified Off The switch is operational Green STS The switch is booting up Flashing amber Temperature exceeds the minor alarm threshold Amber Temperature exceeds the major alarm threshold Red The switch is not receiving power Off Fans and power supply modules are operational Green E...

Page 66: ...Color LED The fan module is operational Green STS The fan module is not operational fan is probably not functional Red Fan module is not receiving power Off Power Supply LEDs The power supply LEDs are located on the left front portion of the power supply Combinations of states indicated by the Okay and Fault LEDs indicate the status for the module as shown in the following table Status LED LED Pow...

Page 67: ...f the following conditions High voltage High power Low voltage Power supply installed in chassis but not connected to a power source Slow power supply fan Flashing amber Green Cisco Nexus 9332PQ ACI Mode Switch Hardware Installation Guide 57 LEDs LEDs ...

Page 68: ...Cisco Nexus 9332PQ ACI Mode Switch Hardware Installation Guide 58 LEDs LEDs ...

Page 69: ... Description Illustration 1 Rack mount kit Front brackets 2 Rear brackets 2 Slider rails 2 M4 Phillips pan head screws 6 1 Ground lug kit Two hole lug 1 M4 x 8 mm Phillips pan head screws 2 1 EAC Compliance document Not applicable 1 Hazardous substances list for customers in China Not applicable The following table lists and illustrates the console cable CAB CONSOLE RJ45 that can be ordered Cisco ...

Page 70: ...ket 2 Slider rails 2 M4 x 7 mm mounting screws 16 1 Ground lug kit Two hole lug 1 M4 x 8 mm Phillips pan head screws 2 1 EAC Compliance document Not applicable 1 Hazardous substances list for customers in China Not applicable The following table lists and illustrates the console cable CAB CONSOLE RJ45 that can be ordered Quantity Description Illustration 1 Console cable with DB 9F and RJ 45F conne...

Page 71: ...on and accessibility The following table lists the site planning tasks that we recommend that you complete before you install the switch Your completion of each task ensures a successful switch installation Verification Time and Date Planning Activity Space evaluation Space and layout Floor covering Impact and vibration Lighting Physical access Maintenance access Environmental evaluation Ambient t...

Page 72: ...enter ground Cable and interface equipment evaluation Cable type Connector type Cable distance limitations Interface equipment transceivers EMI evaluation Distance limitations for signaling Site wiring RFI levels Contact and Site Information Use the following worksheet to record contact and site information for the installation Contact person Contact phone Cisco Nexus 9332PQ ACI Mode Switch Hardwa...

Page 73: ...al number Product number Use the following worksheet to record network related information Switch IP address Switch IP netmask Hostname Domain name IP broadcast address Gateway router address DNS address Use the following worksheet to record information about the modules in the switch Notes Module Serial Number Module Type Module Slot Fan module 1 Cisco Nexus 9332PQ ACI Mode Switch Hardware Instal...

Page 74: ... Type Module Slot Fan module 2 Fan module 3 Fan module 4 Power Supply 1 Power Supply 2 Cisco Nexus 9332PQ ACI Mode Switch Hardware Installation Guide 64 Site Preparation and Maintenance Records Site Preparation and Maintenance Records ...

Reviews: