Step 4
Prepare the other end of the grounding wire and connect it to the facility ground.
Installing the Airflow Sleeve (NXA-AIRFLOW-SLV3)
The airflow sleeve (NXA-AIRFLOW-SLV3) is installed one of two ways. The first way is to install the airflow
sleeve alone. The second way is to install the vent bracket (NXA-ACC-BAV2) along with the airflow sleeve.
If you choose to install them both, then you will install the vent bracket first and then the airflow sleeve.
You require the vent bracket (NXA-ACC-BAV2) for NEBS (Network Equipment-Building System) compliance
only.
Note
You supply the 10-32 or 12-24 screws to mount the vent bracket and airflow sleeve.
Note
Before you begin
• Verify that your shipment is complete.
• Install your rack in a secure location.
Step 1
Insert the vent bracket and attach it as follows:
a) Holding the vent bracket (NXA-ACC-BAV2), position it in front and above the switch (see item 1 in the following
figure).
b) Holding the vent bracket level, insert screws (12-24 or 10-32, depending on the rack type) in each of the front
rack-mount flanges (using a total of two screws) and into the cage nuts or threaded holes in the vertical rack-mounting
rails (see item 2 in the following figure).
Cisco Nexus 93240YC-FX2 NX-OS Mode Switch Hardware Installation Guide
28
Installing the Switch Chassis
Installing the Airflow Sleeve (NXA-AIRFLOW-SLV3)