MS220-24/48 Series (EOS) Installation Guide

Models

Model number

Description

MS220-24

Layer-2 24-port GigabitEthernet switch with 4 SFP
interfaces

MS220-24P

Layer-2 24-port GigabitEthernet 370W PoE switch
with 4 SFP interfaces

MS220-48

Layer-2 48-port GigabitEthernet switch with 4 SFP
interfaces

MS220-48LP

Layer-2 48-port GigabitEthernet 370W PoE switch
with 4 SFP interfaces

MS220-48FP

Layer-2 48-port GigabitEthernet 740W PoE switch
with 4 SFP interfaces

Package contents

In addition to the MS switch, the following are provided (mounting kit provided with 1U models only):

On Mar 16, 2017, Cisco Meraki announced the end-of-sale date for the MS220-24/48 series switch
will be Jul 29, 2017. The end-of-support date is Jul 29, 2024.

Read more about our

Product End-of-Life (EOL) Policy

.

1

Summary of Contents for MS220-24/48 Series

Page 1: ...rfaces MS220 48LP Layer 2 48 port GigabitEthernet 370W PoE switch with 4 SFP interfaces MS220 48FP Layer 2 48 port GigabitEthernet 740W PoE switch with 4 SFP interfaces Package contents In addition to the MS switch the following are provided mounting kit provided with 1U models only On Mar 16 2017 Cisco Meraki announced the end of sale date for the MS220 24 48 series switch will be Jul 29 2017 The...

Page 2: ...ews and cage nuts 5 of each Mounting washers MS220 24 Series front panel MS220 48 Series front panel Ports and Status Indicators The MS uses LEDs to inform the user of the device s status When the device powers on all the Internet LEDs flash twice Additional functions are described below from left to right Item Function LED Status Meaning 2 ...

Page 3: ...on to clear switch IP and local configuration settings 3 Switch Ports Off No client connected Solid orange Link operating at 10 100 Mbps Solid green Link operating at 1000 Mbps In addition there is a RESTORE button available on the front panel Insert a paper clip if a restore is required A brief momentary press To delete a downloaded configuration and reboot Press and hold for more than 10 sec To ...

Page 4: ...port failover and reversion to main power once it has been restored The following Cisco part numbers are supported Part number Description PWR RPS2300 RPS Chassis C3K PWR 750WAC 750W RPS Power supply see recommendations C3K PWR 1150WAC 1150W RPS Power supply see recommendations CAB RPS2300 E RPS 22 pin cable Equipment is to be used only in a restricted access location and installed operated only b...

Page 5: ...4 and 3 x MS220 48 switches connected to my RPS2300 3 x 18W 54W 3 x 51W 153W 54W 153W 207W total power draw Recommended hardware 1 x PWR RPS2300 1 x C3K PWR 750WAC 750W OR 2 x C3K PWR 750WAC 750W for redundancy 6 x CAB RPS2300 E Example 2 I have 6 x MS220 24P switches connected to my RPS2300 I also intend to use the full PoE budget of 370W on each switch and want to back it up in case of a failure...

Page 6: ...58W total power draw Recommended hardware 1 x PWR RPS2300 1 x C3K PWR 750WAC 750W OR 2 x C3K PWR 750WAC 750W for redundancy 6 x CAB RPS2300 E Mounting hardware The mounting hardware includes a rack mount kit for standard 1U racks When installing the device make sure that there is sufficient space between the rear of the rack and other obstacles to ensure adequate airflow Only the RPS2300 chassis P...

Reviews: