2140
2130
2120
2110
Specification
100/240 V AC 2.9 A (at 100 VAC), 50 to
60 Hz
The power supply module is
rated at 6.3 A, but the system
power is limited to 2.9 A.
Note
100/240V AC 1.9 A (at 100 VAC), 50 to
60 Hz
The power supply module is
rated at 4 A, but the system
power is limited to 1.9 A.
Note
System power
Operating: 32 to 104°F (0 to 40°C)
Nonoperating: -40 to 149°F (-40 to 65°C) maximum altitude is 40,000 ft
Temperature
Operating altitude: 0 to 13,000 ft (3962 m)
Operating temperature:
• Long Term: 0 to 45°C up to 6000 ft (1829 m)
• Long Term: 0 to 35°C 6000-13000 ft (1829-3964 m)
• Short Term: -5 to 55°C up to 6000 ft (1829 m)
Firepower 2100 series NEBS compliance applies only to the 2130.
Note
NEBS
Operating: 10 to 85 % noncondensing
Nonoperating: 5 to 95 % noncondensing
Humidity
Operating: 10,000 ft maximum
Nonoperating: 40,000 ft maximum
Altitude
55.7 dBA (typical)
76.7 dBA (maximum)
47.3 dBA (typical)
73.4 dBA (maximum)
Sound pressure
66 (typical)
84.5 (maximum)
60.2 (typical)
85.1 (maximum)
Sound power
Product ID Numbers
The following table lists the PIDs associated with the Firepower 2100 series. All of the PIDs in the table are
field-replaceable. If you need to get a return material authorization (RMA) for any component, see
for more information.
See the
show inventory
and
show inventory expand
commands in the
Cisco FXOS Troubleshooting Guide
to display a list of the PIDs for your Firepower 2100. Or see the
show inventory
command in the
Cisco Firepower Threat Defense Command Reference
or the
to display a list of the PIDs for your Firepower 2100.
Note
Cisco Firepower 2100 Series Hardware Installation Guide
34
Overview
Product ID Numbers