3-12
Cisco CSS UCS Platform Series User Guide, CPS-UCS-1RU-K9 / CPS-UCS-2RU-K9
Chapter 3 Installing the Server
Installing the Cisco Connected Safety and Security UCS C240 Server In a Rack
Installing the Cable Management Arm (Optional)
To install the cable management arm (CMA) to the rear of the slide rails, use the following procedure.
Note
The CMA is reversible right-to-left. However when reversing, you must remove and reposition
the CMA attachment tabs for correct installation. To reverse the CMA, see
Management Arm (Optional), page 3-14
before installation.
Note
When positioning the CMA, make sure that the CMA is correctly oriented with the “TOP” stamp
on the CMA arms facing upward. See
.
Step 1
With the server pushed fully into the rack, insert the outer CMA tab into the clip inside the rear of the
outer slide rail. Insert the tab into the clip until it clicks and locks.
Step 2
Pull outward on the spring-loaded peg that is on the inner CMA tab. You can turn this peg 90 degrees to
lock it in the open position.
Step 3
Push the inner CMA tab over the end of the inner rail that is attached to the server, and then release the
spring-loaded peg.
The spring-loaded peg must align with and enter the hole in the inner rail to lock the CMA in place. If
you turned the peg 90 degrees to lock it open, now turn it back 90 degrees to release it.