Behavior
Color
LED Label
No.
Present.
Blue
SSD slot status
7
Present with failure.
Amber
All fans are operating.
Blue
Fan status
8
One fan has stopped
working.
Amber
Two or more fans have
stopped.
Blinking amber
Present and currently
being used
Blinking blue
eMMC/SD flash status
9
Fault detected
Amber
BMC boot is complete,
intel is powered up
Blue
eMMC/SD flash status
10
BMC is rebooting, intel is
powered up
Blinking Blue
BMC boot is complete,
intel powered down.
Amber
BMC is booting, intel
powered down.
Blinking amber
System is powered on.
Blue
Cisco logo
11
PSU in failure mode.
Amber
PSU failure
12
Hardware Features - Replaceable and Upgradable Units
The replaceable and upgradable units of the Cisco 5400 ENCS are:
•
Power supply:
The power supply provides AC power. The ENCS5406/K9 device supports only the
non-PoE power supply option. This means the LAN ports of this device cannot provide Power over
Ethernet (PoE). The ENCS5408/K9 and ENCS5412/K9 devices support both the PoE and non-PoE power
supply options. If you want to upgrade from a non-POE power supply to a POE power supply, you can
do that by replacing the power supply unit. The reverse is also possible - replacing a POE power supply
with a non-POE power supply. The power supply can supply a total of 250 watts of inline power across
the 8 PoE capable ports in the system; a maximum of 30 watts of PoE power per port and 60 watts of
UPoE power per port.
•
Network Interface Module (NIM):
You can install a NIM in the NIM slot. Similarly when not needed,
you can remove the NIM from the NIM module. The device supports only one NIM at a time. The
following NIMs are currently supported:
Cisco 5400 Enterprise Network Compute System Hardware Installation Guide
12
Overview of the Cisco 5400 Enterprise Network Compute System
Hardware Features - Replaceable and Upgradable Units