Configuring OBFL
We recommend that you do not disable OBFL and that you do not remove the data stored in the flash memory.
Caution
•
• To enable OBFL, use the
hw-switch switch
[
switch-number
]
logging onboard
[
message level level
]
global configuration command. On switches, the range for
switch-number
is from 1 to 9. Use the
message
level level
parameter to specify the severity of the hardware-related messages that the switch generates
and stores in the flash memory.
The following applies to the C9500-12Q, C9500-16X, C9500-24Q, C9500-40X models of the Cisco
Catalyst 9500 Series Switches. To enable OBFL, use the
hw-switch switch
[
module-number
]
logging
onboard
{
application-name
} global configuration command.
• To copy the OBFL data to the local network or a specific file system, use the
copy onboard switch
switch-number url url-destination
privileged EXEC command.
This does not apply to the C9500-12Q, C9500-16X, C9500-24Q, C9500-40X
models of the Cisco Catalyst 9500 Series Switches.
Note
• To disable OBFL, use the
no hw-switch switch
[
switch-number
]
logging onboard
[
message level
]
global configuration command.
The following applies to the C9500-12Q, C9500-16X, C9500-24Q, C9500-40X models of the Cisco
Catalyst 9500 Series Switches. To disable OBFL, use the
no hw-module slot
[
module-number
]
logging
onboard
{
application-name
} global configuration command.
• To clear all the OBFL data in the flash memory except for the uptime and CLI command information,
use the
clear onboard switch switch-number
privileged EXEC command.
The following applies to the C9500-12Q, C9500-16X, C9500-24Q, C9500-40X models of the Cisco
Catalyst 9500 Series Switches. To disable OBFL, use the
no hw-module slot
[
module-number
]
logging
onboard
{
application-name
} global configuration command.
To clear all the OBFL data in the flash memory except for the uptime, use the
clear logging onboard
RP active
{
application
} privileged EXEC command.
• In a switch stack, you can enable OBFL on a standalone switch or on all stack members by using the
hw-switch switch
[
switch-number
]
logging onboard
[
message level level
] global configuration command.
• The following does not apply to the C9500-12Q, C9500-16X, C9500-24Q, C9500-40X models of the
Cisco Catalyst 9500 Series Switches. To disable OBFL, use the
no hw-module slot
[
module-number
]
logging onboard
{
application-name
} global configuration command.
You can enable or disable OBFL on a member switch from the active switch.
For more information about the commands in this section, see the command reference for this release.
System Management Configuration Guide, Cisco IOS XE Fuji 16.8.x (Catalyst 9500 Switches)
284
Troubleshooting the Software Configuration
Configuring OBFL