47-28
Catalyst 4500 Series Switch, Cisco IOS Software Configuration Guide - Cisco IOS XE 3.9.xE and IOS 15.2(5)Ex
Chapter 47 Configuring Private VLANs
Configuring PVLANs
This example shows how to configure interface port channel 63 as a secondary trunk port, and to verify
the configuration:
Switch#
configure terminal
Switch(config)#
interface port-channel 63
Switch(config-if)#
switchport mode private-vlan trunk secondary
Switch(config-if)#
switchport private-vlan trunk native vlan 10
Switch(config-if)#
switchport private-vlan trunk allowed vlan 10. 3-4
Switch(config-if)#
switchport private-vlan association trunk 3 301
Switch(config-if)#
end
Switch#
show interfaces port-channel 63 switchport
Name: Po63
Switchport: Enabled
Administrative Mode: private-vlan trunk secondary
Operational Mode: private-vlan trunk secondary
Administrative Trunking Encapsulation: negotiate
Operational Trunking Encapsulation: dot1q
Negotiation of Trunking: On
Access Mode VLAN: 1 (default)
Trunking Native Mode VLAN: 1 (default)
Administrative Native VLAN tagging: enabled
Voice VLAN: none
Administrative private-vlan host-association: none
Administrative private-vlan mapping: none
Administrative private-vlan trunk native VLAN: 10
Administrative private-vlan trunk Native VLAN tagging: enabled
Administrative private-vlan trunk encapsulation: dot1q
Administrative private-vlan trunk normal VLANs: none
Administrative private-vlan trunk associations:
3 (VLAN0003) 301 (VLAN0301)
Administrative private-vlan trunk mappings: none
Operational private-vlan: none
Operational Normal VLANs: none
Trunking VLANs Enabled: ALL
Pruning VLANs Enabled: 2-1001
Capture Mode Disabled Capture VLANs Allowed: ALL
Unknown unicast blocked: disabled
Unknown multicast blocked: disabled
Appliance trust: none
Configuring a Layer 2 Etherchannel as a Promiscuous PVLAN Trunk Port
To configure a Layer 2 Etherchannel as a promiscuous PVLAN trunk port, perform this task:
Command
Purpose
Step 1
Switch#
configure terminal
Enters global configuration mode.
Step 2
Switch(config)#
interface port
-
channel
interface
-
number
Specifies the LAN interface to configure.
Step 3
Switch(config-if)#
switchport mode private-vlan
{
host
|
promiscuous
|
trunk promiscuous
|
trunk
[
secondary
]}
Configures a Layer 2 Etherchannel as a
PVLAN promiscuous trunk port.
Step 4
Switch(config-if)# [
no
]
switchport private-vlan
mapping
[
trunk
]
primary_vlan_ID
{
secondary_vlan_list
|
add
secondary_vlan_list
|
remove
secondary_vlan_list
}
Maps the promiscuous PVLAN port to a
primary VLAN and to the selected secondary
VLANs.
This command offers 3 levels of removal.
Summary of Contents for Catalyst 4500 Series
Page 2: ......
Page 4: ......
Page 2086: ...Index IN 46 Software Configuration Guide Release IOS XE 3 9 0E and IOS 15 2 5 E ...