Attaching Module Interface Cables
Caution
Use extreme care when removing or installing connectors so that you do not damage the connector
housing or scratch the end-face surface of the fiber. Always install protective covers on unused or
disconnected components to prevent contamination. Always clean fiber connectors before installing
them.
Figure 11
SC-Type Fiber-Optic Connector
LC Connector
Warning
Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into
beams or view directly with optical instruments.
Statement 1051
The LC fiber-optic connector, shown in
Figure 12
, is a small form-factor fiber-optic connector that
provides high-density fiber connectivity. The LC connector can be used with either MMF cable or SMF
cable. The LC connector uses a latching clip mechanism that is similar to the one used on the RJ-45
copper connector.
Note
Make sure that the optical connectors are clean before making the connections. Contaminated connectors
can damage the fiber and cause data errors.
Figure 12
LC Fiber-Optic Connector
Cable
Plug
Receptacle
Keys
Receiv
er
Transmitter
Light out
of fiber
Light into
fiber
13087
Key slots
58476