3-9
Catalyst 3560 Switch Hardware Installation Guide
78-16057-01
Chapter 3 Switch Installation
Preparing for Installation
Note
When using shorter distances of single-mode fiber cable, you might need to insert
an inline optical attenuator in the link to avoid overloading the receiver.
When the fiber-optic cable span is less than15.43 miles (25 km), you should insert
a 5-decibel (dB) or 10-dB inline optical attenuator between the fiber-optic cable
plant and the receiving port on the 1000BASE-ZX SFP module at each end of the
link.
•
Operating environment is within the ranges listed in
•
Clearance to front and rear panels is such that
–
Front-panel indicators can be easily read.
–
Access to ports is sufficient for unrestricted cabling.
–
Rear-panel power connector is within reach of an AC power receptacle.
•
Cabling is away from sources of electrical noise, such as radios, power lines,
and fluorescent lighting fixtures. Make sure the cabling is safely away from
other devices that might damage the cables.
CWDM
1470, 1490,
1510, 1530,
1550, 1570,
1590, 1610
SMF
9/125
—
62 miles (100 km)
1.
A mode-conditioning patch cord is required. Using an ordinary patch cord with MMF, 1000BASE-LX/LH SFP modules, and
a short link distance can cause transceiver saturation, resulting in an elevated bit error rate (BER). When using the LX/LH
SFP module with 62.5-micron diameter MMF, you must also install a mode-conditioning patch cord between the SFP module
and the MMF cable on both the sending and receiving ends of the link. The mode-conditioning patch cord is required for link
distances greater than 984 feet (300 m).
2.
1000BASE-ZX SFP modules can send data up to 62 miles (100 km) by using dispersion-shifted SMF or low-attenuation
SMF; the distance depends on the fiber quality, the number of splices, and the connectors.
Table 3-1
Fiber-Optic SFP Module Port Cabling Specifications (continued)
SFP Module
Wavelength
(nanometers)
Fiber Type
Core Size
(micron)
Modal
Bandwidth
(MHz/km)
Cable Distance
Summary of Contents for Catalyst 3560
Page 6: ......
Page 12: ...Contents x Catalyst 3560 Switch Hardware Installation Guide 78 16057 01 ...
Page 23: ...xxi Catalyst 3560 Switch Hardware Installation Guide 78 16057 01 Preface Conventions ...
Page 24: ...Preface Conventions xxii Catalyst 3560 Switch Hardware Installation Guide 78 16057 01 ...
Page 25: ...xxiii Catalyst 3560 Switch Hardware Installation Guide 78 16057 01 Preface Conventions ...