background image

 

A-1

Catalyst 3750-X and 3560-X Switch Hardware Installation Guide

OL-19593-01

A P P E N D I X

A

Technical Specifications

Switch Specifications, page A-1

Power Supply Module Specifications, page A-2

Fan Module Specifications, page A-4

Switch Specifications

Table A-1

 Environmental and Physical Specifications

Environmental Ranges

Operating temperature

32 to 113° F (0 to 45° C)

Storage temperature

–13 to 158° F (–25 to 70° C)

Relative humidity

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3049 m)

Storage altitude

Up to 15,000 ft (4573 m), NEBS up to 13,000 ft (4000 m)

Physical Specifications

Summary of Contents for Catalyst 3560-X-24P

Page 1: ... 2 Fan Module Specifications page A 4 Switch Specifications Table A 1 Environmental and Physical Specifications Environmental Ranges Operating temperature 32 to 113 F 0 to 45 C Storage temperature 13 to 158 F 25 to 70 C Relative humidity 10 to 85 noncondensing Operating altitude Up to 10 000 ft 3049 m Storage altitude Up to 15 000 ft 4573 m NEBS up to 13 000 ft 4000 m Physical Specifications ...

Page 2: ...X and 3560 X 48T Catalyst 3750 X and 3560 X 48P Catalyst 3750 X and 3560 X 48PF 1 75 x 17 5 x 18 0 in 4 45 x 44 5 x 46 0 cm 1 75 x 17 5 x 18 0 in 4 45 x 44 5 x 46 0 cm 1 75 x 17 5 x 18 0 in 4 45 x 44 5 x 46 0 cm 1 75 x 17 5 x 18 0 in 4 45 x 44 5 x 46 0 cm 1 75 x 17 5 x 19 5 in 4 45 x 44 5 x 49 5 cm Note The C3KX PWR 1100 W AC power supply extends 1 5 in 3 8 cm beyond the switch chassis 1 With C3KX...

Page 3: ...WR 715WAC 715 W C3KX PWR 350WAC 350 W Input voltage range and frequency C3KX PWR 1100WAC 1100 W 115 to 240 VAC autoranging 50 to 60 Hz C3KX PWR 715WAC 715 W C3KX PWR 350WAC 350 W 100 to 240 VAC autoranging 50 to 60 Hz Input current C3KX PWR 1100WAC 12 6 A C3KX PWR 715WAC 10 5 A C3KX PWR 350WAC 4 2 A Output ratings C3KX PWR 1100WAC 56 V 19 64 A C3KX PWR 715WAC 56 V 12 8 A C3KX PWR 350WAC 56 V 6 25 ...

Page 4: ...DC maximum Total input BTU1 1 The total input and total output BTU ratings refer to input power to the power supply and output power to the switch The BTU ratings are based on 36 VDC C3KX PWR 440WDC 1841 Btus per hour 540 W Total output BTU1 C3KX PWR 440WDC 1502 Btus per hour 440 W Wire gauge for ground connection C3KX PWR 440WDC 12 AWG or 8 AWG Branch circuit protection C3KX PWR 440WDC 20 A Table...

Page 5: ...ds and Certifications Description Specification Electromagnetic compatibility certifications FCC Part 15 Class A EN55022 Class A CISPR22 EN55024 CISPR24 CE VCCI Class A AS NZS CISPR22 Class A MIC China EMC certifications GOST Environmental Reduction of Hazardous Substances ROHS 5 Noise specifications Office product spec 48 dBA at 86º F 30º C Telco CLEI code ...

Page 6: ...A 6 Catalyst 3750 X and 3560 X Switch Hardware Installation Guide OL 19593 01 Appendix A Technical Specifications Fan Module Specifications ...