Maintenance and Upgrade

Power Button Shut Down, on page 1

Enable RPC, on page 2

Reset the Chassis Remotely, on page 3

Install/Uninstall the Locking Faceplate, on page 3

Remove and Replace a Drive, on page 4

Remove and Replace a Power Supply, on page 7

Power Button Shut Down

The chassis runs in two modes:

• Main power mode—Power is supplied to all components and all operating systems can run.

• Standby power mode—Power is supplied only to the service processor and certain components. You can

safely remove power cords from the chassis in this mode.

After you shut down the chassis to standby power, electric current is still present in the chassis. To completely
remove power as directed in some maintenance procedures, you must disconnect all power cords from all
power supplies in the chassis.

Caution

You can shut down the chassis using the front panel Power button or software management.

Step 1

Check the Power LED:

• Amber—The chassis is already in standby mode and you can safely remove power.

• Green—The chassis is in main power mode and you must shut it down before you can safely remove power.

Step 2

Perform a graceful shutdown or a hard shutdown:

To avoid data loss or damage to your operating system, perform a graceful shutdown of the operating system.

Caution

• Graceful shutdown—Press and release the Power button. The operating system performs a graceful shutdown and

the chassis goes into standby mode. The power LED is amber.

Maintenance and Upgrade

1

Summary of Contents for C195

Page 1: ...t in the chassis To completely remove power as directed in some maintenance procedures you must disconnect all power cords from all power supplies in the chassis Caution You can shut down the chassis using the front panel Power button or software management Step 1 Check the Power LED Amber The chassis is already in standby mode and you can safely remove power Green The chassis is in main power mod...

Page 2: ...cycle chassis power you must have a third party tool that supports the Intelligent Platform Management Interface IPMI version 2 0 Step 1 Use SSH or the serial console port to access the CLI Step 2 Log in using an account with Administrator access Step 3 Enter the following commands remotepower setup Step 4 Follow the prompts to specify the following The dedicated IP address for the RPC port netmas...

Page 3: ... 2 for more information Note For example issue the following command from a UNIX computer with IPMI support ipmitool I lan H ip address U remoteresetuser P password chassis power reset Step 2 Wait at least 11 minutes for the chassis to reboot Install Uninstall the Locking Faceplate The locking faceplate Cisco part number 74 115098 01 for a 1 RU chassis and Cisco part number 74 115099 01 for a 2 RU...

Page 4: ...y push in as the faceplate is installed Step 3 Lock the faceplate using the key that shipped with the faceplate Step 4 To uninstall the faceplate unlock the faceplate push the latch to the right and pull the faceplate out Remove and Replace a Drive The drives are hot swappable You do not have to shut down the chassis to remove or replace drives Note Maintenance and Upgrade 4 Maintenance and Upgrad...

Page 5: ...nd conductor Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available Warning Statement 1030 Equipment Installation Only trained and qualified personnel should be allowed to install replace or service this equipment Warning Statement 1073 No User Serviceable Parts No serviceable parts inside To avoid risk of electric shock ...

Page 6: ... 2 Ejector handle 1 Step 2 Remove the four drive tray screws that secure the drive to the tray and then lift the drive out of the tray Figure 3 Remove the Drive Tray Maintenance and Upgrade 6 Maintenance and Upgrade Remove and Replace a Drive ...

Page 7: ...assis one power supply might actively provide all power to the system while the remaining power supply is put into a standby state For example if the power consumption can be satisfied by power supply 1 then power supply 2 is put into a standby state When you replace power supplies do not mix power supply types in the chassis Both power supplies must be the same wattage and Cisco PID Caution Power...

Page 8: ...e Parts No serviceable parts inside To avoid risk of electric shock do not open Warning Statement 1074 Comply with Local and National Electrical Codes To reduce risk of electric shock or fire installation of the equipment must comply with local and national electrical codes Warning Step 1 Remove the power supply that you are replacing or the blank panel from an empty bay a Do one of the following ...

Page 9: ...e and insert the new power supply into the empty bay b Push the power supply into the bay until the release lever locks c Connect the power cord to the new power supply d If you shut down the chassis press the Power button to return it to main power mode Maintenance and Upgrade 9 Maintenance and Upgrade Remove and Replace a Power Supply ...

Page 10: ...Maintenance and Upgrade 10 Maintenance and Upgrade Remove and Replace a Power Supply ...