![Cisco BTS 10200 Softswitch Troubleshooting Manual Download Page 733](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550733.webp)
15-107
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 15 Diagnostic Tests
Pre-Manual Switchover Switch Integrity Diagnostic Utility
Operating
There are three new CLI commands related to the BTS 10200 Tabular Display of Events and Alarms
feature correlating to the following:
•
Show current alarms in tabular format
•
Show alarms history in tabular format
•
Show events history in tabular format
CLI Commands
The following are CLI commands and there description:
•
show tab-alarm
—Shows current alarms in tabular format
•
show tab-alarm-hist
—Shows alarms history in tabular format
•
show tab-event-hist
—Shows events history in tabular format
An example of the output of executing of one the three commands follows:
CLI>s
how tab-alarm
Pre-Manual Switchover Switch Integrity Diagnostic Utility
This section describes the Pre-Manual Switchover Switch Integrity Diagnostic Utility feature that
provides the switchover target system health information. For costly traffic outages to be avoided, the
switchover decision must be made based on the system health information. The diagnostic script utility
automates the manual procedures that are used to collect, check, and verify system health information.
The Cisco BTS 10200 Softswitch Pre-Manual Switchover Switch Integrity Diagnostic Utility feature
provides the system health information of the switchover target so that Cisco BTS 10200 Softswitch
customers can decide if they want to perform manual switchover.
The customer service provider operation organizations often periodically perform switchovers during
maintenance windows (after midnight and early in the morning). Doing so ensures that the mate system
is functional and cleans up any abnormalities that might have accumulated in the current active/primary
system (e.g., memory leaks, hung processes).
In order to facilitate the switchover operational practice, the Cisco BTS 10200 Softswitch Pre-Manual
Switchover Switch Integrity Diagnostic Utility feature provides a diagnostic tool/utility that allows the
operator to verify the operational status of the standby system/platform and decide whether it is in a
ready state for a switchover.
Note
See the
Cisco BTS 10200 Softswitch Network and Subscriber Feature Descriptions
guide for a complete
list of subscriber features supported by the Cisco BTS 10200 Softswitch.
ID
TYPE
NUMBER
SEVERITY
TIMESTAMP
COMPONENT-ID
12331874656
SIGNALING
68
MAJOR
2005-11-20 11:00:00
testing@mgw_id
12331874657
MAINTENANCE
3
MAJOR
2005-11-20 11:01:00
testing
12331874658
OSS
9
MINOR
2005-11-20 11:02:45
unixserver
12331874659
OSS
9
MINOR
2005-11-20 11:02:45
skittles