Chapter 15 Diagnostic Tests
Signaling System 7 Trunk Termination Tests
Signaling System 7 Trunk Termination Tests
This section describes the tests that can be performed on Signaling System 7 (SS7) trunk terminations.
All terminations must be in the MAINT state for testing.
Step 1
Force the SS7 trunk termination into MAINT state:
control ss7-trunk-termination tgn-id=103; mode=forced; target-state=maint;
Note
Set customer-originated trace (COT), circuit verification message (CVM), and circuit query
message (CQM) on the terminating gateway or switch to perform these tests. Otherwise, the test
or tests will fail.
Step 2
Display the Test Menu.
diag ss7-trunk-termination
Reply Example:
Reply: Diagnostic SS7 Trunk Group Menu.
===
Test 1: SS7 MGCP Connectivity Test
Test 2: SS7 Termination Connection Test
Test 3: SS7 COT Test
Test 4: SS7 CQM Test
Test 5: SS7 CVT Test
Test 6: SS7 CIC Audit
Test 0: ALL Tests
Note
Test #1 tests if MGCP has access to the SS7 trunk termination.
Test #2 tests if there is a path to the device (ping).
Test #3 tests the integrity of the SS7 Bearer Path.
Test #4 queries the SS7 circuit (or group of circuits) status. A range of CICs can be specified (to a
maximum of 24). Both remote and local trunk states are displayed in the results.
Test #5 tests to ensure that each end of the circuit has sufficient and consistent information for using the
circuit in call connections. Common language location identifier (CLLI) names are included.
Test #6 tests to ensure the CIC connections.
Test #0 performs tests 1 through 6.