![Cisco BTS 10200 Softswitch Troubleshooting Manual Download Page 609](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550609.webp)
14-35
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 14 General Troubleshooting
Protocol Troubleshooting
Checking the Status of a Trunk Termination
Check the status of a trunk termination using the following command:
status trunk-termination tgn-id=<trunk group number;cic=<cic number;
Reply : Success:
RESULT -ADM configure result in success
REASON -ADM executed successful
TGN ID -2
CIC -8
TERM ADMIN STATE -ADMIN_INS
TERM OPER STATE -Termination is idle
TERM REASON -No fault reason available
TRUNK STATIC STATE -ACTV
TRUNK DYNAMIC STATE -TRNS
TRUNK REASON -NON_FAULTY
The above status shows that the trunk is active, in idle mode, and ready for call use.
If the trunk static state is set to locally blocked, go to the
“Trunk Static State Is Set to Locally Blocked”
section.
If the trunk static state is set to transient (TRNS), go to the
“Trunk Static State Is Set to Transient”
section.
If the trunk static state is set to remotely blocked, go to the
“Trunk Static State Is Set to Remote Block”
section.
If the trunk static state is set to TERM_STATUS_FAULTY, go to the
“Termination Status Is Faulty”
section.
If the trunk static state returns Cannot Make Call, go to the
section.