Chapter 10 Signaling Troubleshooting
Monitoring Signaling Events
Set Trunk State as NOT Remotely Blocked—Signaling (52)
The Set Trunk State as NOT Remotely Blocked event functions as an informational alert that the trunk
state has been set as not remotely blocked. The primary cause of the event is that the specified CIC is
marked as not remotely blocked due to the CQM response indicating that it is not remotely blocked at
the far end. The event is informational and no further action is required.
Set Trunk State as Remotely Blocked—Signaling (53)
The Set Trunk State as Remotely Blocked event functions as an informational alert that the trunk state
is set as remotely blocked. The primary cause of the event is that the specified CIC is marked as remotely
blocked due to the CQM response indicating that it is remotely blocked at the far end. To correct the
primary cause of the event, clear the blocking situation at the far end based on network level event
reports.
Circuit Validation Test Aborted—Signaling (54)
The Circuit Validation Test Aborted event functions as an informational alert that the circuit validation
test has been aborted. The primary cause of the event is that the circuit specified failed a validation test
due to an internal failure. To correct the primary cause of the event, verify the SS7 signaling adapter
process and SS7 interface is operating normally.
Circuit Validation Successful—Signaling (55)
The Circuit Validation Successful event functions as an informational alert that the circuit validation
was successful. The event is informational and no further actions is required.
Continuity Recheck Failed—Signaling (57)
The Continuity Recheck Failed event functions as an informational alert that the continuity recheck
failed. The primary cause of the event is that a continuity recheck of the specified CIC failed. To correct
the primary cause of the event, verify the SS7 signaling adapter process and SS7 interface is operating
normally.
Continuity Recheck Successful—Signaling (58)
The Continuity Recheck Successful event functions as an informational alert that the continuity recheck
of the specified CIC was successful. The event is informational and no further action is required.