Signaling Events and Alarms
SIGNALING (147)
To monitor and correct the cause of the event, refer to the
“Domain Name System Service Addresses
Exhausted—Signaling (147)” section on page 10-121
.
SIGNALING (148)
SIGNALING (148) is not used.
SIGNALING (149)
SIGNALING (149) is not used.
SIGNALING (150)
To troubleshoot and correct the cause of the alarm, refer to the
“Stream Control Transmission Protocol
Association Congested—Signaling (150)” section on page 10-156
.
DESCRIPTION
Domain Name System Service Addresses Exhausted (DNS SRV Addresses Exhausted)
SEVERITY
WARNING
THRESHOLD
100
THROTTLE
0
DATAWORDS
SRV Hostname–STRING [256]
PRIMARY
CAUSE
The DNS service (SRV) hostname resolution to the IP address is exhausted.
PRIMARY
ACTION
Add an entry to the SRV in the DNS server. Fix the BTS 10200 provisioning.
DESCRIPTION
Stream Control Transmission Protocol Association Congested (SCTP Association Congested)
SEVERITY
MINOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
SCTP Association ID–STRING [17]
Congestion Level–ONE_BYTE
PRIMARY
CAUSE
The network is congested.
PRIMARY
ACTION
Clean off the network congestion caused by the routing or switching issues.
SECONDARY
CAUSE
The central processing unit (CPU) is throttled.
SECONDARY
ACTION
You may need to upgrade to a more powerful platform or offload some traffic.