![Cisco BTS 10200 Softswitch Troubleshooting Manual Download Page 445](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550445.webp)
10-77
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (145)
To troubleshoot and correct the cause of the alarm, refer to the
“One Internet Protocol Interface to
Signaling System 7 Signaling Gateway is Down—Signaling (145)” section on page 10-156
SIGNALING (146)
To monitor and correct the cause of the event, refer to the
“All Retransmission Attempts of Session
Initiation Protocol Request or Response Failed—Signaling (146)” section on page 10-121
.
DESCRIPTION
One Internet Protocol Interface to Signaling System 7 Signaling Gateway is Down (One IP Interface
to SS7 Signaling Gateway is Down)
SEVERITY
MINOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Interface Name–STRING [65]
Interface IP Address–STRING [65]
PRIMARY
CAUSE
A hardware problem has occurred.
PRIMARY
ACTION
Check the link interfaces.
DESCRIPTION
All Retransmission Attempts of Session Initiation Protocol Request or Response Failed (All
Retransmission Attempts of SIP Request or Response Failed)
SEVERITY
WARNING
THRESHOLD
100
THROTTLE
0
DATAWORDS
SIP Request Type–STRING [15]
Sender IP–STRING [20]
PRIMARY
CAUSE
SIP request: All retransmission attempts for a SIP request failed for the DNS or the IP address of
request uniform resource identifier (URI). SIP response: All retransmission attempts for a SIP response
failed for the received socket IP address of the request and the DNS (or the IP address) listed in the
header.
PRIMARY
ACTION
Ensure that if DNS server is up and running for the host name resolution and is provisioned properly
to resolve the correct order of the IP addresses. Ensure that the previous hop network component is
alive and in a healthy state for failures related to the SIP responses.